Observational Study
. 2022 Jul 6;61(7):2951-2958.
doi: 10.1093/rheumatology/keab700.

Consumer-based activity trackers in evaluation of physical activity in myositis patients

Affiliations
Observational Study

Consumer-based activity trackers in evaluation of physical activity in myositis patients

Didem Saygin et al. Rheumatology (Oxford). .

Abstract

Objectives: Inflammatory myopathies are characterized by muscle weakness that limits the activities of daily living. Daily step count is an accepted metric of physical activity. Wearable technologies such as Fitbit® enable tracking of daily step counts. We assessed the psychometric properties of Fitbit® and compared the accuracy of Fitbit® step counts to ActiGraph®.

Methods: This was a pilot, proof of concept, prospective observational study with four visits at 0, 1, 3 and 6 months in PM, DM, necrotizing myopathy (NM) or anti-synthetase syndrome (AS) subjects. Six core set measures (manual muscle testing, physician global disease activity, patient global disease activity, and extra-muscular disease activity, HAQ-Disability Index and creatine kinase), three functional tests (six-min walk, timed up-and-go, sit-to-stand tests) and SF-36 physical function-10 (PF10) were collected at each visit. Patients wore waist-worn Fitbit® One and ActiGraph® T3X-BT concurrently for 7 days/month for 6 months.

Results: Twenty-four (10 DM, 8 PM/NM, 6 AS) patients (17 females/7 males; 91% Caucasian) were enrolled. Test-retest reliability of daily steps was strong in 1-month follow-up (ICC 0.89). Daily steps and peak 1-min cadence showed moderate-strong correlations with physician global disease activity, patient global disease activity, HAQ-Disability Index, SF-36 PF10 and all three functional tests. Fitbit® and ActiGraph® step counts demonstrated good agreement and strong correlation (ICC 0.96).

Conclusion: Fitbit® daily steps and peak 1-min cadence are reliable and valid measures of physical activity in a cohort of myositis patients. This pilot data suggests that Fitbit® has a potential for use in clinical practice and trials to monitor physical activity in myositis patients, but larger studies are needed for further validation.

Keywords: Fitbit; myositis; physical activity monitor.