Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2021 Nov;47(6):101283.
doi: 10.1016/j.diabet.2021.101283. Epub 2021 Sep 18.

Glycaemic variabilities: Key questions in pursuit of clarity

Affiliations
Review

Glycaemic variabilities: Key questions in pursuit of clarity

L Ouis Monnier et al. Diabetes Metab. 2021 Nov.

Abstract

After years of intensive investigation, the definition of glycaemic variability remains unclear and the term variability in glucose homoeostasis might be more appropriate covering both short and long-term glycaemic variability. For the latter, we remain in the search of an accurate definition and related targets. Recent work leads us to consider that the within-subject variability of HbA1c calculated from consecutive determinations of HbA1c at regular time-intervals could be the most relevant index for assessing the long-term variability with a threshold value of 5% (%CV = SD of HbA1c/mean HbA1c) to separate stability from lability of HbA1c. Presently, no one can deny that short- and long-term glucose variability should be maintained within their lower ranges to limit the incidence of hypoglycaemia. Usually, therapeutic strategies aimed at reducing post-meal glucose excursions, i.e. the major contributor to daily glucose fluctuations, exert a beneficial effect on the short-term glucose variability. This explains the effectiveness of adjunct therapies with either GLP- receptor agonists or SGLT inhibitors in type 2 diabetes. In type 1 diabetes, the application of a CGM device alone reduces the short-term glycaemic variability. In contrast, sophisticated insulin delivery does not necessarily lead to such reductions despite marked downward shifts of 24-hour glycaemic profiles. Such contrasting observations raise the question as to whether the prolonged wear of CGM devices is or not the major causative factor for improvement in glucose variability among intensively insulin-treated persons with type 1 diabetes.

Keywords: Glucose variabilities; New questions; Pending answers.

PubMed Disclaimer

Conflict of interest statement

Declaration of interests The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper

MeSH terms

LinkOut - more resources