Incidence and Risk Factors for a Malpositioned Intrauterine Device Detected on Three-Dimensional Ultrasound Within Eight Weeks of Placement
- PMID: 34580900
- DOI: 10.1002/jum.15836
Incidence and Risk Factors for a Malpositioned Intrauterine Device Detected on Three-Dimensional Ultrasound Within Eight Weeks of Placement
Abstract
Objectives: To estimate the incidence of intrauterine device (IUD) malpositioning detected on three-dimensional (3D) transvaginal ultrasound within 8 weeks of placement and identify risk factors for malpositioning.
Methods: Retrospective study of women who had an IUD placed at a large obstetrics and gynecology practice from January 1, 2015, to December 31, 2020. All patients underwent two-dimensional ultrasound at the time of insertion and routine three-dimensional ultrasound within 8 weeks. Baseline characteristics and potential risk factors were compared between women with correctly positioned and malpositioned IUDs. Odds ratios were calculated by logistic regression to identify risk factors independently associated with malpositioning.
Results: A total of 763 IUD placements were included, and 127 malpositioned IUDs were identified representing an overall rate of malpositioning of 16.6% (95% confidence interval [CI] 14.0-19.3) with 8.8% (95% CI 6.8-10.8) requiring removal. Patients with malpositioned IUD had higher rates of morbid obesity (13.4% versus 3.8%, adjusted odds ratio [aOR] 2.46, 95% CI 1.10-5.50), prior uterine window or rupture (9.0% versus 2.2%, aOR 2.78, 95% CI 1.06-7.30), copper IUD placement (64.2% versus 47.4%, aOR 1.99, 95% CI 1.31-3.03), and symptoms such as bleeding or pain at follow-up (35.8% versus 20.1%, aOR 2.58, 95% CI 1.67-3.98). Parity, breastfeeding, difficult insertion, and uterine size and positioning were not significant.
Conclusions: The incidence of malpositioned IUD within 8 weeks of placement on 3D ultrasound is 16.6%, with 8.8% requiring removal. Significant risk factors for malpositioning include morbid obesity, prior uterine window or rupture, and copper IUD placement. These findings support the importance of routine follow-up 3D ultrasound after seemingly successful IUD placement.
Keywords: intrauterine device; intrauterine device malposition; long-acting reversible contraception; three-dimensional ultrasound; ultrasound.
© 2021 American Institute of Ultrasound in Medicine.
Similar articles
-
CT imaging of intrauterine devices (IUD): expected findings, unexpected findings, and complications.Abdom Radiol (NY). 2024 Jan;49(1):237-248. doi: 10.1007/s00261-023-04052-3. Epub 2023 Oct 31. Abdom Radiol (NY). 2024. PMID: 37907685 Review.
-
Uterine structural abnormality and intrauterine device malposition: analysis of ultrasonographic and demographic variables of 517 patients.Am J Obstet Gynecol. 2019 Feb;220(2):183.e1-183.e8. doi: 10.1016/j.ajog.2018.11.122. Epub 2018 Nov 9. Am J Obstet Gynecol. 2019. PMID: 30419198
-
Malpositioned intrauterine contraceptive devices: risk factors, outcomes, and future pregnancies.Obstet Gynecol. 2011 Nov;118(5):1014-1020. doi: 10.1097/AOG.0b013e3182316308. Obstet Gynecol. 2011. PMID: 22015868
-
Association of Intrauterine Device Malposition With Previous Cesarean Delivery and Related Uterine Anatomical Changes.J Ultrasound Med. 2024 Jun;43(6):1121-1129. doi: 10.1002/jum.16440. Epub 2024 Feb 29. J Ultrasound Med. 2024. PMID: 38421056
-
Modern intra-uterine devices.Baillieres Clin Obstet Gynaecol. 1996 Apr;10(1):55-67. doi: 10.1016/s0950-3552(96)80062-9. Baillieres Clin Obstet Gynaecol. 1996. PMID: 8736722 Review.
Cited by
-
CT imaging of intrauterine devices (IUD): expected findings, unexpected findings, and complications.Abdom Radiol (NY). 2024 Jan;49(1):237-248. doi: 10.1007/s00261-023-04052-3. Epub 2023 Oct 31. Abdom Radiol (NY). 2024. PMID: 37907685 Review.
-
The lost intrauterine levonorgestrel-releasing system in women with adenomyosis: A case report.SAGE Open Med Case Rep. 2022 Nov 29;10:2050313X221135725. doi: 10.1177/2050313X221135725. eCollection 2022. SAGE Open Med Case Rep. 2022. PMID: 36478966 Free PMC article.
-
Perforation of levonorgestrel-releasing intrauterine system found at one month after insertion: A case report.World J Clin Cases. 2023 Jan 6;11(1):172-176. doi: 10.12998/wjcc.v11.i1.172. World J Clin Cases. 2023. PMID: 36687185 Free PMC article.
-
PCOS and Obesity: Contraception Challenges.Open Access J Contracept. 2025 May 5;16:43-58. doi: 10.2147/OAJC.S501434. eCollection 2025. Open Access J Contracept. 2025. PMID: 40352401 Free PMC article. Review.
-
Ineffective Pelvic Magnetic Resonance Imaging for the Detection of a Levonorgestrel-releasing Intrauterine System Straying into the Abdominal Cavity.Gynecol Minim Invasive Ther. 2025 May 22;14(2):174-177. doi: 10.4103/gmit.GMIT-D-24-00009. eCollection 2025 Apr-Jun. Gynecol Minim Invasive Ther. 2025. PMID: 40521579 Free PMC article.
References
-
- Committee on Practice Bulletins-Gynecology, Long-Acting Reversible Contraception Work Group. Practice bulletin no. 186: long-acting reversible contraception: implants and intrauterine devices. Obstet Gynecol 2017; 130:e251-e269.
-
- Braaten KP, Benson CB, Maurer R, Goldberg AB. Malpositioned intrauterine contraceptive devices: risk factors, outcomes, and future pregnancies. Obstet Gynecol 2011; 118:1014-1020.
-
- Gerkowicz SA, Fiorentino DG, Kovacs AP, Arheart KL, Verma U. Uterine structural abnormality and intrauterine device malposition: analysis of ultrasonographic and demographic variables of 517 patients. Am J Obstet Gynecol 2019; 220:183.e181-e188.
-
- Moschos E, Twickler DM. Does the type of intrauterine device affect conspicuity on 2D and 3D ultrasound? AJR Am J Roentgenol 2011; 196:1439-1443.
-
- Benacerraf BR, Shipp TD, Bromley B. Three-dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are a source of pelvic pain and abnormal bleeding. Ultrasound Obstet Gynecol 2009; 34:110-115.
MeSH terms
LinkOut - more resources
Full Text Sources