Wound closure with Dexon (polyglycolic acid) mass suture
- PMID: 345927
- PMCID: PMC2491961
Wound closure with Dexon (polyglycolic acid) mass suture
Abstract
A series of 814 consectuvie laparotomy incisions at three hospitals were closed with No 2 Dexon (polyglycolic acid) sutures using the 'near and far' technique. The incidence of wound dehiscence was 0.5%, of sinus formation 1%, and of incisional hernia 2.2% at 6 months and 6% at 3 years.