Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Oct 3:27:e932745.
doi: 10.12659/MSM.932745.

Assessment of Color Stainability of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) Ceramic Materials After Hot and Cold Coffee Immersion at Different Time Intervals

Affiliations

Assessment of Color Stainability of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) Ceramic Materials After Hot and Cold Coffee Immersion at Different Time Intervals

Hafiz A Adawi et al. Med Sci Monit. .

Abstract

BACKGROUND This spectrophotometric study assessed the color stability of CAD/CAM restorative materials with different exposed surfaces following staining by hot Arabic Qahwa and cold coffee. MATERIAL AND METHODS Ninety-six specimens were fabricated from 3 different CAD/CAM ceramic materials: Vita Suprinity (Vita-S), Vita Enamic (Vita-E), and Vitablocs Mark II (Vitablocs-MII). We divided 32 specimens for each group into glazed or polished surfaces, with 16 specimens in each group, then subdivided them according to staining materials: Arabic Qahwa and Frappuccino Cold Coffee. Color of specimens was measured during immersion in staining materials (BEFORE) as baseline with (Vita classic) and (L, a, b), for average color changes (ΔE₀₀), then remeasured after 2, 4, and 12 weeks, and described as 1st, 2nd, and 3rd measurements for VITAPAN Classic shade and T1, T2, and T3 for ΔE00 values using the CIE L*a*b* equation. We performed ANOVA and then post hoc testing. RESULTS We found significant differences in ΔE₀₀ values during immersing in hot Arabic Qahwa and cold coffee for tested materials in glazed or polished specimens. Polished specimens of Vita-S and Vita-E had the highest color changing and staining compared to glazed surfaces. Vitablocs-MII had the best color stability through immersion periods. Moreover, there were changes in relation to VITAPAN Classic shade guide for both Vita-S and Vita-E specimens during different immersion periods. CONCLUSIONS Coffee caused staining and contamination of ceramic material. Values of ΔE₀₀ for tested ceramic materials were significantly different but were within the clinically acceptable range. Polished specimens showed higher staining; therefore, we highly recommend re-glazing of ceramic restorations to maintain color stability.

PubMed Disclaimer

Conflict of interest statement

Conflicts of interest

None.

Figures

Figure 1
Figure 1
A diagram showing the design of the study and sequences of research steps.
Figure 2
Figure 2
Representative SEM image of tested CAD/CAM materials “Vita Suprinity, Vita Enamic, and Vitablocs Mark II” at ×250 magnification after staining and aging.
Figure 3
Figure 3
Mean and SD values of color changes of different type of ceramic at different time intervals in relation to surface type and staining materials.

References

    1. Giordano R. Materials for chairside CAD/CAM-produced restorations. J Am Dent Assoc. 2006;137:S14–21. - PubMed
    1. Colombo M, Poggio C, Lasagna A, et al. Vickers micro-hardness of new restorative CAD/CAM dental materials: Evaluation and comparison after exposure to acidic drink. Materials (Basel) 2019;12(8):1246. - PMC - PubMed
    1. Erozan Ç, Ozan O. Evaluation of the precision of different intraoral Scanner-Computer Aided Design (CAD) software combinations in digital dentistry. Med Sci Monit. 2020;26:e918529. - PMC - PubMed
    1. Lambert H, Durand J-C, Jacquot B, Fages M. Dental biomaterials for chairside CAD/CAM: State of the art. J Adv Prosthodont. 2017;9(6):486–95. - PMC - PubMed
    1. Giti R, Haghdoost S, Ansarifard E. Effect of different coloring techniques and surface treatment methods on the surface roughness of monolithic zirconia. Dent Res J. 2020;17:152–61. - PMC - PubMed