Reproducibility of rotational panoramic radiography: mandibular linear dimensions and angles
Abstract
The reproducibility of nine mandibular variables (linear dimensions and angles) assessed from panoramic radiographs with the Orthopantomograph 5 (Siemens) was investigated. Attention was given to the possible influence of recording the reference number of the head positioner with one or two radiographers. Two separate exposures of three groups of patients were made under different radiographic conditions, each group representing one method. Acceptable reproducibility was observed for the vertical and angular variables, the method variance being mostly within 3% of the total variance. Horizontal variables were clearly more unreliable. No statistically significant differences were observed between the reproducibility of the right and left sides. A negative correlation was found between the angular variables within two groups. For most variables, only small differences among the methods were found. The highest reliability was obtained when the same radiographer recorded the reference number of the head positioner and made both exposures. An accuracy study on five dried skulls showed an image magnification of approximately 18% to 21% for the vertical variables, whereas the gonial angle assessed from a panoramic film was almost identical to that measured on the dried mandible.
Similar articles
-
[Research methods in dentistry 9. Follow-up of permucosal implants in an edentate mandible using panoramic radiography].Ned Tijdschr Tandheelkd. 2005 Mar;112(3):86-9. Ned Tijdschr Tandheelkd. 2005. PMID: 15792391 Review. Dutch.
-
Accuracy of measurements of mandibular anatomy and prediction of asymmetry in panoramic radiographic images.Dentomaxillofac Radiol. 2005 Nov;34(6):343-9. doi: 10.1259/dmfr/28020783. Dentomaxillofac Radiol. 2005. PMID: 16227476
-
Standardized panoramic radiography in assessment of mandibular augmentation with hydroxylapatite material: preliminary report.J Oral Maxillofac Surg. 1989 Jul;47(7):724-9. doi: 10.1016/s0278-2391(89)80014-x. J Oral Maxillofac Surg. 1989. PMID: 2543803
-
Does the panoramic radiography have the power to identify the gonial angle in orthodontics?ScientificWorldJournal. 2012;2012:219708. doi: 10.1100/2012/219708. Epub 2012 Dec 13. ScientificWorldJournal. 2012. PMID: 23365514 Free PMC article.
-
Mandibular asymmetry diagnosis with panoramic imaging.Am J Orthod Dentofacial Orthop. 2008 Aug;134(2):183-92. doi: 10.1016/j.ajodo.2007.07.021. Am J Orthod Dentofacial Orthop. 2008. PMID: 18675198 Review.
Cited by
-
Comparison of gonial angle determination from cephalograms and orthopantomogram.Indian J Dent. 2014 Jul;5(3):123-6. doi: 10.4103/0975-962X.140820. Indian J Dent. 2014. PMID: 25565740 Free PMC article.
-
Effects of the Vertical Malocclusion Types on the Dimension of the Mandibular Condyle.Turk J Orthod. 2017 Dec;30(4):106-109. doi: 10.5152/TurkJOrthod.2017.17029. Epub 2017 Dec 1. Turk J Orthod. 2017. PMID: 30112501 Free PMC article.
-
Assessment of condyle-coronoid angle and gonial angle for gender determination: A digital panoramic study in Bagalkot population.J Oral Maxillofac Pathol. 2022 Jul-Sep;26(3):414-418. doi: 10.4103/jomfp.jomfp_74_22. Epub 2022 Oct 17. J Oral Maxillofac Pathol. 2022. PMID: 36588824 Free PMC article.
-
Evaluation of factors influencing the success rate of orthodontic microimplants using panoramic radiographs.Korean J Orthod. 2018 Jan;48(1):30-38. doi: 10.4041/kjod.2018.48.1.30. Epub 2017 Nov 19. Korean J Orthod. 2018. PMID: 29291186 Free PMC article.
-
Sex determination by mandibular ramus: A digital orthopantomographic study.J Forensic Dent Sci. 2016 May-Aug;8(2):95-8. doi: 10.4103/0975-1475.186367. J Forensic Dent Sci. 2016. PMID: 27555726 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources