Polyethylene liner cementation into a well-fixed metal acetabular shell for the management of periacetabular osteolysis: a systematic review
- PMID: 34605989
- DOI: 10.1007/s00590-021-03130-w
Polyethylene liner cementation into a well-fixed metal acetabular shell for the management of periacetabular osteolysis: a systematic review
Abstract
Purpose: Although various papers have reported on the clinical performance of cup retention with cementation of a new liner and bone grafting in the management of well-fixed cups with polyethylene wear and periacetabular osteolysis after total hip arthroplasty (THA), no systematic review of this topic has been published to date.
Methods: Medline, EMBASE and Cochrane Library were searched for articles published from January 1999 to January 2019 using "osteolysis" AND "well-fixed", "osteolysis" AND "retro-acetabular", "bone graft" AND ("retention" OR "retained" OR "stable") AND "cup", and "cemented liner" AND "well-fixed".
Results: Nine articles were selected for review (186 cases, 76.1 months mean follow-up). The overall revision rate was 11.3% (21 hips) most commonly due to aseptic loosening (9/186 hips), dislocation (8/186 hips), and liner wear progression (2/186 cases). The reported square size of osteolytic lesions ranged from a mean of 465.84 mm2 to a max of 4,770 mm2. Almost all reported lesions treated with bone grafts resolved or did not progress 97% (72/74). All studies indicated improved pain and functional scores at follow-up.
Conclusion: Cementation of a new liner with periacetabular bone grafting provides an alternative option to isolated liner exchange and cup revision for the management of periacetabular osteolysis in well-fixed cups with a disrupted locking mechanism or unavailable exchange liner. Further higher quality studies are required in order to examine if the use of highly cross-linked polyethylene, highly porous-coated cups, hydroxyapatite-coated cups, and small-diameter cups influence the clinical outcome of liner cementation in well-fixed cups with periacetabular osteolysis.
Keywords: Bone grafting; Cemented liner; Periacetabular osteolysis; Polyethylene liner; Systematic review; Well-fixed.
© 2021. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.
Similar articles
-
Isolated Liner Exchange and Bone Grafting for the Management of Periacetabular Osteolysis in Well-Fixed Cups with an Intact Locking Mechanism at Short-Term to Medium-Term Follow-Up: A Systematic Review.HSS J. 2024 Nov;20(4):567-576. doi: 10.1177/15563316231189736. Epub 2023 Sep 7. HSS J. 2024. PMID: 39494435 Review.
-
Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?Clin Orthop Relat Res. 2013 Nov;471(11):3572-80. doi: 10.1007/s11999-013-3144-y. Epub 2013 Aug 3. Clin Orthop Relat Res. 2013. PMID: 23913339 Free PMC article.
-
Is There a Role for Greater Trochanteric Osteotomies in Isolated Acetabular Revisions?J Arthroplasty. 2025 Aug;40(8S1):S273-S277. doi: 10.1016/j.arth.2025.03.078. Epub 2025 May 13. J Arthroplasty. 2025. PMID: 40633986
-
Threaded cup in total hip arthroplasty: a systematic review of long-term survivorship.Eur J Orthop Surg Traumatol. 2025 Jun 5;35(1):236. doi: 10.1007/s00590-025-04364-8. Eur J Orthop Surg Traumatol. 2025. PMID: 40473846
-
Trabecular metal versus non-trabecular metal acetabular components for acetabular revision surgery: A systematic review and meta-analysis.Int J Surg. 2022 Apr;100:106597. doi: 10.1016/j.ijsu.2022.106597. Epub 2022 Mar 11. Int J Surg. 2022. PMID: 35288338
Cited by
-
Massive Periacetabular Osteolysis Treated With Acetabular Cup Retention and Cemented Screw Fixation.Arthroplast Today. 2025 Jan 2;31:101595. doi: 10.1016/j.artd.2024.101595. eCollection 2025 Feb. Arthroplast Today. 2025. PMID: 39850463 Free PMC article.
-
Isolated Liner Exchange and Bone Grafting for the Management of Periacetabular Osteolysis in Well-Fixed Cups with an Intact Locking Mechanism at Short-Term to Medium-Term Follow-Up: A Systematic Review.HSS J. 2024 Nov;20(4):567-576. doi: 10.1177/15563316231189736. Epub 2023 Sep 7. HSS J. 2024. PMID: 39494435 Review.
References
-
- Kim YH, Kim JS, Cho SH (1999) Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty 14(5):538–548 - DOI
-
- Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 91(1):128–133 - DOI
-
- Delaunay C, Hamadouche M, Girard J, Duhamel A (2013) SoFCOT Group: What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471(12):3863–3869 - DOI
-
- Hozack WJ, Mesa JJ, Carey C, Rothman RH. Relationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components. A framework for decision making. J Arthroplasty 1996;11(7):769–72.
-
- Hall A, Eilers M, Hansen R, et al: Advances in acetabular reconstruction in revision total hip arthroplasty: maximizing function and outcomes after treatment of periacetabular osteolysis around the well-fixed shell. J Bone Joint Surg Am. 2013;18;95(18):1709–18.