Detection of spontaneous seizures in EEGs in multiple experimental mouse models of epilepsy
- PMID: 34607322
- DOI: 10.1088/1741-2552/ac2ca0
Detection of spontaneous seizures in EEGs in multiple experimental mouse models of epilepsy
Abstract
Objective.Electroencephalography (EEG) is a key tool for non-invasive recording of brain activity and the diagnosis of epilepsy. EEG monitoring is also widely employed in rodent models to track epilepsy development and evaluate experimental therapies and interventions. Whereas automated seizure detection algorithms have been developed for clinical EEG, preclinical versions face challenges of inter-model differences and lack of EEG standardization, leaving researchers relying on time-consuming visual annotation of signals.Approach.In this study, a machine learning-based seizure detection approach, 'Epi-AI', which can semi-automate EEG analysis in multiple mouse models of epilepsy was developed. Twenty-six mice with a total EEG recording duration of 6451 h were used to develop and test the Epi-AI approach. EEG recordings were obtained from two mouse models of kainic acid-induced epilepsy (Models I and III), a genetic model of Dravet syndrome (Model II) and a pilocarpine mouse model of epilepsy (Model IV). The Epi-AI algorithm was compared against two threshold-based approaches for seizure detection, a local Teager-Kaiser energy operator (TKEO) approach and a global Teager-Kaiser energy operator-discrete wavelet transform (TKEO-DWT) combination approach.Main results.Epi-AI demonstrated a superior sensitivity, 91.4%-98.8%, and specificity, 93.1%-98.8%, in Models I-III, to both of the threshold-based approaches which performed well on individual mouse models but did not generalise well across models. The performance of the TKEO approach in Models I-III ranged from 66.9%-91.3% sensitivity and 60.8%-97.5% specificity to detect spontaneous seizures when compared with expert annotations. The sensitivity and specificity of the TKEO-DWT approach were marginally better than the TKEO approach in Models I-III at 73.2%-80.1% and 75.8%-98.1%, respectively. When tested on EEG from Model IV which was not used in developing the Epi-AI approach, Epi-AI was able to identify seizures with 76.3% sensitivity and 98.1% specificity.Significance.Epi-AI has the potential to provide fast, objective and reproducible semi-automated analysis of multiple types of seizure in long-duration EEG recordings in rodents.
Keywords: EEG; Epi-AI; artificial intelligence; epilepsy; experimental mouse models; machine learning; seizure detection.
Creative Commons Attribution license.
Similar articles
-
Artificial intelligence system, based on mjn-SERAS algorithm, for the early detection of seizures in patients with refractory focal epilepsy: A cross-sectional pilot study.Epilepsy Behav Rep. 2023 Apr 5;22:100600. doi: 10.1016/j.ebr.2023.100600. eCollection 2023. Epilepsy Behav Rep. 2023. PMID: 37252270 Free PMC article.
-
Automatic seizure detection using orthogonal matching pursuit, discrete wavelet transform, and entropy based features of EEG signals.Comput Biol Med. 2021 Apr;131:104250. doi: 10.1016/j.compbiomed.2021.104250. Epub 2021 Feb 4. Comput Biol Med. 2021. PMID: 33578071
-
Accurate detection of spontaneous seizures using a generalized linear model with external validation.Epilepsia. 2020 Sep;61(9):1906-1918. doi: 10.1111/epi.16628. Epub 2020 Aug 6. Epilepsia. 2020. PMID: 32761902 Free PMC article.
-
Wavelet-based EEG processing for computer-aided seizure detection and epilepsy diagnosis.Seizure. 2015 Mar;26:56-64. doi: 10.1016/j.seizure.2015.01.012. Epub 2015 Jan 24. Seizure. 2015. PMID: 25799903 Review.
-
Artificial intelligence/machine learning for epilepsy and seizure diagnosis.Epilepsy Behav. 2024 Jun;155:109736. doi: 10.1016/j.yebeh.2024.109736. Epub 2024 Apr 17. Epilepsy Behav. 2024. PMID: 38636146 Review.
Cited by
-
Development and validation of a multimodal automatic interictal epileptiform discharge detection model: a prospective multi-center study.BMC Med. 2025 Aug 15;23(1):479. doi: 10.1186/s12916-025-04316-3. BMC Med. 2025. PMID: 40817241 Free PMC article.
-
Automated Classification of Sleep-Wake States and Seizures in Mice.bioRxiv [Preprint]. 2025 Jun 2:2023.04.07.536063. doi: 10.1101/2023.04.07.536063. bioRxiv. 2025. PMID: 37066377 Free PMC article. Preprint.
-
Memristive Neural Networks for Predicting Seizure Activity.Sovrem Tekhnologii Med. 2023;15(4):30-38. doi: 10.17691/stm2023.15.4.03. Epub 2023 Jul 28. Sovrem Tekhnologii Med. 2023. PMID: 38434190 Free PMC article.
-
Prospects of Electrocorticography in Neuropharmacological Studies in Small Laboratory Animals.Brain Sci. 2024 Jul 31;14(8):772. doi: 10.3390/brainsci14080772. Brain Sci. 2024. PMID: 39199466 Free PMC article. Review.
-
Electroencephalographic differences between waking and sleeping periods in patients with prolonged disorders of consciousness at different levels of consciousness.Front Hum Neurosci. 2025 Feb 17;19:1521355. doi: 10.3389/fnhum.2025.1521355. eCollection 2025. Front Hum Neurosci. 2025. PMID: 40034215 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical