Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Nov;91(11):2507-2513.
doi: 10.1111/ans.17247. Epub 2021 Oct 5.

Evaluating the validity of ultrasound in diagnosing hypertrophic pyloric stenosis: a cross-sectional diagnostic accuracy study

Affiliations

Evaluating the validity of ultrasound in diagnosing hypertrophic pyloric stenosis: a cross-sectional diagnostic accuracy study

Toby Vinycomb et al. ANZ J Surg. 2021 Nov.

Abstract

Background: Our aims were to evaluate the ultrasound scan (USS) criteria in diagnosing hypertrophic pyloric stenosis (HPS), determine the best diagnostic threshold values for pyloric muscle thickness (PMT) and pyloric canal length (PCL), and assess the accuracy of flow through the pylorus.

Methods: All patients who underwent pyloromyotomy at our tertiary paediatric surgery centre between July 2013 and June 2019 were identified (Group 1). All patients undergoing an USS to investigate for a possible HPS and did not undergo pyloromyotomy were also identified (Group 2). Accuracy was determined by Youden's Index (J) with the highest J determining the ideal cut-off value.

Results: Two hundred and eighty-four patients (142 patients in each group) were included in the analysis. Using only the last USS before surgery, PMT provided an area under the curve (AUC) of 0.987 (n = 275), and PCL an AUC of 0.977 (n = 267). Ideal threshold values were 3.0 mm for PMT (J = 0.92), and 14.5 mm for PCL (J = 0.87). Combining PMT ≥3.0 mm with a PCL ≥14.5 mm resulted in a sensitivity of 95% and specificity of 99% (J = 0.94). The absence of flow through the pylorus on dynamic USS provided a sensitivity of 99% and specificity of 91% (J = 0.91; n = 277).

Conclusion: Combining threshold values of 3.0 mm for PMT and 14.5 mm PCL provides the highest accuracy for diagnosing pyloric stenosis on an ultrasound scan. These combined values were more accurate than observing for the absence of flow through the pylorus.

Keywords: diagnostic imaging; pyloric stenosis; pyloromyotomy; ultrasonography.

PubMed Disclaimer

References

    1. MacMahon B. The continuing enigma of pyloric stenosis of infancy: a review. Epidemiology 2006; 17: 195-201. https://doi.org/10.1097/01.ede.0000192032.83843.c9.
    1. Teele RL, Smith EH. Ultrasound in the diagnosis of idiopathic hypertrophic pyloric stenosis. N. Engl. J. Med. 1977; 296: 1149-50. https://doi.org/10.1056/nejm197705192962006.
    1. Hernanz-Schulman M. Pyloric stenosis: role of imaging. Pediatr. Radiol. 2009; 39(Suppl 2): S134-9. https://doi.org/10.1007/s00247-008-1106-4.
    1. Stunden RJ, LeQuesne GW, Little KE. The improved ultrasound diagnosis of hypertrophic pyloric stenosis. Pediatr. Radiol. 1986; 16: 200-5. https://doi.org/10.1007/bf02456287.
    1. Blumhagen JD, Maclin L, Krauter D, Rosenbaum DM, Weinberger E. Sonographic diagnosis of hypertrophic pyloric stenosis. AJR Am. J. Roentgenol. 1988; 150: 1367-70. https://doi.org/10.2214/ajr.150.6.1367.

LinkOut - more resources