Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2021 Dec:115:103837.
doi: 10.1016/j.jdent.2021.103837. Epub 2021 Oct 5.

Randomized clinical split-mouth study on the performance of CAD/CAM-partial ceramic crowns luted with a self-adhesive resin cement or a universal adhesive and a conventional resin cement after 39 months

Affiliations
Free article
Randomized Controlled Trial

Randomized clinical split-mouth study on the performance of CAD/CAM-partial ceramic crowns luted with a self-adhesive resin cement or a universal adhesive and a conventional resin cement after 39 months

Konstantin J Scholz et al. J Dent. 2021 Dec.
Free article

Abstract

Objectives To determine the clinical performance of partial ceramic crowns (PCCs) luted with a conventional resin cement combined with a universal adhesive without or with selective enamel etching or luted with a self-adhesive resin cement. Methods In a split-mouth design, each three CAD/CAM-PCCs (Vita Mark II, Cerec) were placed in 50 patients. Two PCCs were luted with a conventional resin cement (RelyX Ultimate) combined with a universal adhesive (Scotchbond Universal) without (SB-E) or with (SB+E) selective enamel etching. The third PCC was luted with a self-adhesive resin cement (RelyX Unicem 2; RXU). Chi-square tests (α≤0.05) were applied. Based on clinical failures (complete debonding or need for replacement of the restorations), Kaplan-Meier survival analysis was performed. Results 31 patients were evaluated clinically using FDI criteria at 39 months. Clinically acceptable results were detected over time, except for "fracture of material and retention" (inacceptable fractures and debondings). Within materials, statistically significant differences (p ≤ 0.003) between baseline and 39 months were found for "marginal adaptation" and "marginal staining". At 39-month, SB+E and SB-E showed significantly better results compared to RXU in "marginal adaptation"(p ≤ 0.021) and "marginal staining"(p ≤ 0.013). Kaplan-Meier analysis showed higher survival rates after 39 months for SB+E (96%) and SB-E (88%) compared to RXU (69%) with statistically significant differences between RXU vs. SB-E (p = 0.022) and RXU vs. SB+E (p ≤ 0.001). Conclusions After 39-months, PCCs luted with the self-adhesive resin cement exhibited a statistically significant inferior survival rate compared to restorations luted with the conventional resin cement combined with a universal adhesive without or with selective enamel etching. Clinical significance Currently, self-adhesive resin cements cannot be recommended for luting partial ceramic crowns. However, the standard adhesive luting procedure comprising a universal adhesive and luting composite yielded good clinical results for more than 3 years irrespectively of application of a selective enamel etching step.

Keywords: CAD/CAM; Clinical study; Partial ceramic crowns; Selective enamel etching; Self-adhesive resin cements; Universal adhesive.

PubMed Disclaimer

Publication types

Associated data