Development, construction, and validation of a thinner uniplanar calibration cage for radiostereometry

Affiliations
Free article

Development, construction, and validation of a thinner uniplanar calibration cage for radiostereometry

Jonathan Hugo Jürgens-Lahnstein et al. J Orthop Res. 2022 Jul.
Free article

Abstract

Radiostereometric analysis (RSA) is an accurate and precise radiographic method that can be used to measure micromotion of implants and study joint kinematics in vivo. A calibration cage with radiopaque markers is used to calibrate the RSA images; however, the thickness (250 mm) of the calibration cage restricts the available area for the patient and equipment during RSA recordings. A thinner calibration cage would increase the recording area, facilitate handling of the cage, and ease integration of the cage with the RSA system. We developed a thinner calibration cage without compromise of accuracy and precision. First, we performed numerical simulations of an RSA system, and showed that the calibration cage thickness could be decreased to 140 mm maintaining accuracy and precision using 40 fiducial and 30 control markers. Second, we constructed a new calibration cage (NRT cage) according to the simulation results. Third, we validated the new calibration cage against two state-of-the-art calibration cages (Umeaa cage and Leiden cage) in a phantom study. All cages performed similar for marker-based analysis, except for y-rotation, where the Umeaa cage (SD = 0.064 mm) was less precise compared to the NRT (SD = 0.038 mm) and Leiden cages (0.042 mm) (p = .01). For model-based analysis the NRT cage had superior precision for translations (SD ≤ 0.054 mm) over the Leiden cage (SD ≤ 0.118 mm) and Umeaa cage (SD ≤ 0.093 mm) (p < .01). The combined study confirmed that the new and thinner calibration cage maintained accuracy and precision at the level of existing thicker calibration cages.

Keywords: RSA; arthroplasty; calibration; radiostereometry.

PubMed Disclaimer

References

REFERENCES

    1. Kärrholm J, Borssén B, Löwenhielm G, Snorrason F. 1994. Does early micromotion of femoral stem prostheses matter? J Bone Joint Surg Br 76(6):912-917.
    1. Nieuwenhuijse MJ, Valstar ER, Kaptein BL, Nelissen RGHH. 2012. Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups. J Bone Jt Surg 94(10):874-880.
    1. Pijls BG, Valstar ER, Nouta KA, et al. 2012. Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties. Acta 83(6):614-624.
    1. Pijls BG, Nieuwenhuijse MJ, Fiocco M, et al. 2012. Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies. Acta Orthop. 83(6):583-591.
    1. Ryd L, Albrektsson BE, Carlsson L, et al. 1995. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg Br 77(3):377-383.

Publication types

LinkOut - more resources