The Effects of a Blue-Light Filtering Versus Clear Intraocular Implant on Color Appearance

Affiliations

The Effects of a Blue-Light Filtering Versus Clear Intraocular Implant on Color Appearance

Billy R Hammond Jr et al. Transl Vis Sci Technol. .

Abstract

Purpose: More than a dozen studies have investigated whether blue-light filtering (BLF) intraocular lens (IOL) implants influence color vision, generally finding they do not. These studies have not tested color vision per se; rather, they have measured color vision deficiencies or chromatic discrimination. Here, we used additive trichromatic colorimetry to assess color appearance in participants with BLF and clear IOL.

Methods: Seventy-six participants were recruited from two populations: older participants (n = 52) with BLF and clear IOL (n = 98 eyes; M = 67.33 ± 7.48 years; 58.8% female; 25.5% non-White), and young adult control participants (n = 24; M = 21.0 ± 5.13 years; 70.8% female; 41.5% non-White). Participants used a custom-built tricolorimeter to mix three primaries until a perceived perfect neutral white was achieved. Color appearance, expressed as chromaticity coordinates, was measured with a spectral radiometer (ILS950).

Results: Between subjects, the BLF IOL chromaticity coordinates (x = 0.34, y = 0.35, u' = 0.21, v' = 0.48) were not significantly different from the clear IOL (x = 0.34, y = 0.33, u' = 0.22, v' = 0.48). BLF and clear IOL were also not different within-contralateral subjects (n = 21; BLF x = 0.34, y = 0.33, u' = 0.22, v' = 0.47; clear x = 0.34, y = 0.33, u' = 0.21, v' = 0.48). Both IOL groups differed from young adults (v'[0.45; P = 0.001], x[0.31; P = 0.008], and y[ 0.30, P < 0.000], but not u'[0.21]).

Conclusions: One advantage of geometric representation of color space is the ability to specify the appearance (rather than spectral composition) of any light mixture by specific coordinates. Using this system, only minor differences in color appearance were found between a BLF, clear IOL, and young natural lens.

Translational relevance: When color perception is directly measured, the BLF and clear IOL are not meaningfully different.

PubMed Disclaimer

Conflict of interest statement

Disclosure: B.R. Hammond, Jr, Alcon (C); B.R. Wooten, None; S.E. Saint, None; L. Renzi-Hammond, None

Figures

Figure 1.
Figure 1.
Schematic of the tricolorimeter.
Figure 2.
Figure 2.
Between group comparison of the chromaticity coordinates of the BLF (x) and clear (0)IOL group.

Similar articles

Cited by

References

    1. Dillon J, Zheng L, Merriam JC, Gaillard ER.. Transmission of light to the aging human retina: possible implications for age related macular degeneration. Exp Eye Res. 2004; 79: 753–759, doi:10.1016/j.exer.2004.06.025. - DOI - PubMed
    1. Mäntyjärvi M, Syrjäkoski J, Tuppurainen K, Honkonen V.. Colour vision through intraocular lens. Acta Ophthalmol Scand. 1997; 75(2): 166–169, doi:10.1111/j.1600-0420.1997.tb00116.x. - DOI - PubMed
    1. Delahunt PB, Webster MA, Ma L, Werner JS.. Long-term renormalization of chromatic mechanisms following cataract surgery. Vis Neurosci. 2004;21: 301–307, doi:10.1017/S0952523804213025. - DOI - PMC - PubMed
    1. Granville WC. Colors do cook different after a lens implant! Leonardo. 1991; 24(3): 351, doi:10.2307/1575581. - DOI
    1. Ao M, Li X, Qiu W, Hou Z, Su J, Wang W.. The impact of age-related cataracts on colour perception, postoperative recovery and related spectra derived from test of hue perception. BMC Ophthalmol. 2019; 19(1): 56, doi:10.1186/s12886-019-1057-6. - DOI - PMC - PubMed

Publication types