. 2022 Mar;38(3):621-629.
doi: 10.1007/s10554-021-02452-4. Epub 2021 Oct 24.

The role of three dimensional transesophageal echocardiography novel-score in the success of redo percutaneous balloon mitral valvuloplasty

Affiliations

The role of three dimensional transesophageal echocardiography novel-score in the success of redo percutaneous balloon mitral valvuloplasty

Kadriye Memic Sancar et al. Int J Cardiovasc Imaging. 2022 Mar.

Abstract

Mitral valve commissure evaluation is known to be important in the success of percutaneous balloon mitral valvuloplasty (PBMV) and Wilkins score (WS) is used in clinical practice. In our study, we aimed to determine whether WS in redo PBMV is sufficient in the success of procedure and additionally we have evaluated a novel scoring system including three dimensional (3D) transesophageal echocardiography (TEE) of the mitral valve structure before redo PBMV in terms of success of the procedure. Fifty patients who underwent redo PBMV were included in the study. The patients were divided into two groups according to the success of the Redo PBMV procedure which was defined as post-procedural MVA ≥ 1.5 cm2 and post-procedural mitral regurgitation less than moderate by echocardiographic evaluation after PBMV. A novel score based on 3D TEE findings was created by analyzing the images recorded before Redo PBMV and by evaluating the mitral commissure and calcification. The role of traditional WS and novel score in the success of the procedure were investigated. In the study group, 36 patients (72%) had successful redo PBMV procedure. WS was 8 (IQR 7-9) and novel 3D TEE score was found 4 (IQR 3-4) in the whole study group. While no statistically significant relationship was found between WS and procedural success (p = 0.187), a statistically significant relationship was found between novel 3D TEE score and procedural success (p = 0.042). Specifically, the procedural successes rate was > 90% when novel 3D TEE score was < 4. The novel 3D TEE score might be an informative scoring system in the selection of suitable patients for successful redo PBMV, especially in patients who are considered for surgery due to the high WS.

Keywords: Balloon mitral valvuloplasty; Commissural calcification; Commissural fusion; Transesophageal echocardiography; Wilkins score.

PubMed Disclaimer

References

    1. Inoue K, Owaki T, Nakamura T, Kitamura F, Miyamoto N (1984) Clinical applications of intravenous mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg 87:394–402 - DOI
    1. Lock JE, Khalilullah M, Shrivastava S, Bahl V, Keane JF (1985) Percutaneous catheter commissurotomy in rheumatic mitral stenosis. N Engl J Med 313:1515–1518 - DOI
    1. Iung B, Cormier B, Ducimetiere P et al (1996) Functional results 5 years after successful percutaneous mitral commissurotomy in a series of 528 patients and analysis of predictive factors. J Am Coll Cardiol 27:407–414 - DOI
    1. Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP, Gentile F, Jneid H, Krieger EV, Mack M, McLeod C, O’Gara PT, Rigolin VH, Sundt TM 3rd, Thompson A, Toly C (2021) 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 143(5):e72–e227. https://doi.org/10.1161/CIR.0000000000000923 (Erratum in: Circulation) - DOI - PubMed
    1. Baumgartner H, Falk V, Bax JJ, DeBonis M, Hamm C, Holm PJ et al (2017) 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J 38:2739–2791 - DOI

MeSH terms

LinkOut - more resources