. 2022 Jan;67(1):24-33.
doi: 10.4187/respcare.08850. Epub 2021 Oct 26.

Reducing Device-Related Pressure Injuries Associated With Noninvasive Ventilation in the Neonatal Intensive Care Unit

Affiliations

Reducing Device-Related Pressure Injuries Associated With Noninvasive Ventilation in the Neonatal Intensive Care Unit

J Julia Krzyzewski et al. Respir Care. 2022 Jan.

Abstract

Background: Noninvasive ventilation (NIV) has become the preferable modality of respiratory support for spontaneously breathing premature infants in the neonatal ICU (NICU). Whereas NIV support contributes to the prevention of long-term respiratory sequelae from mechanical ventilation, the nasal interfaces used are well known for placing patients at risk for development of NIV device-related pressure injuries (PIs). After implementing clinical practice guidelines promoting the use of sealing NIV interfaces for respiratory support in a level IV NICU, an increase in the frequency of stage 2 or worse and deep tissue injury (DTI) PI was observed. We hypothesized that the implementation of a multifaceted skin care bundle (SCB) would reduce the incidence of NIV device-related PI.

Methods: Quality improvement methodology was used to evaluate the impact of implementing an SCB for patients supported with NIV via a nasal interface. Incidence rate of stage 2 or worse and DTI PI was reported per 100 NIV days over 4 distinct time periods: (1) pre-NIV guideline, (2) post-NIV guideline, (3) post SCB, and (4) sustainability phase. Incidence comparisons were made using one-sided P values from the Farrington-Manning test of equal risks with a significance level of 0.05.

Results: The NICU experienced a notable rise in NIV device-related PI after implementation of NIV guidelines (0.01 vs 0.34 per 100 NIV days; P = .01). After application of an SCB, a decrease in NIV device-related skin PI was achieved (0.34 vs 0.07 per 100 NIV days; P = .04), representing a 79% reduction.

Conclusions: A collaborative and multidisciplinary team approach was used to promote engagement with clinical staff to address a preventable harm. The implementation of a multifaceted PI prevention bundle contributed to reducing harm while permitting the continued use of appropriate respiratory support to a highly vulnerable patient population in the NICU.

Keywords: device-related pressure injury; neonatal; noninvasive ventilation; pressure injury; pressure ulcer; skin.