Abstract
Ocular ultrasound is an invaluable tool for the evaluation of the eye and orbit. However, the eye and orbit are potentially sensitive to the thermal and mechanical effects of ultrasound. When performing B-mode imaging, dedicated ocular settings should be used. If these settings are not available, limiting the acoustic output to Food and Drug Administration (FDA) recommended maximum levels is strongly advised. Especially important is the acoustic output in spectral (pulsed) and color Doppler modes, which can exceed the FDA's maximum recommended levels for the eye. Adjusting settings to decrease acoustic output and limiting the time of the examination should be done when performing a Doppler examination. The acoustic output of shear wave elastography is significantly higher than FDA guidelines for the eye and should be considered experimental.
Keywords: bioeffects; ophthalmic ultrasound; point of care; safety.
© 2021 American Institute of Ultrasound in Medicine.
References
REFERENCES
-
- Lorente-Ramos RM, Arman JA, Munoz-Hernandez A, et al. US of the eye made easy: a comprehensive how-to review with ophthalmoscopic correlation. Radiographics 2012; 32:E175-E200. https://doi.org/10.1148/rg.325115105.
-
- Almendarez JE, Vargas DM, Gonzalez C, et al. Ultrasound findings in ocular trauma. Arch Soc Esp Oftalmol 2015; 90:572-577. https://doi.org/10.1016/j.oftal.2015.07.010.
-
- Zhang X. Identification of the Rayleigh surface waves for estimation of viscoelasticity using the surface wave elastography technique. J Acoust Soc Am 2016; 140:3619. https://doi.org/10.1121/1.4966673.
-
- Barr RG. Just because there is a button doesn't mean it is appropriate to use or that it will give accurate information. J Ultrasound Med 2019; 38:1139. https://doi.org/10.1002/jum.14990.
-
- Zhang X, McLaren J, Kazemi A, Lin S-C, Pruet CM, Sit AJ. Ultrasound surface wave elastography of the living human eye. IEEE International Ultrasonics Symposium (IUS), Tours, 2016, pp. 1-3, https://doi.org/10.1109/ULTSYM.2016.7728510.