. 2021 Sep 27;13(9):e18319.
doi: 10.7759/cureus.18319. eCollection 2021 Sep.

Evaluating the Sensitivity and Specificity of Siemens Clinitest Lateral Flow Test and the Simple AMplification-Based Assay (SAMBA)-2 PCR Test for SARS-CoV-2 Infection

Affiliations

Evaluating the Sensitivity and Specificity of Siemens Clinitest Lateral Flow Test and the Simple AMplification-Based Assay (SAMBA)-2 PCR Test for SARS-CoV-2 Infection

Adrian A Boyle et al. Cureus. .

Abstract

Introduction Accurate point-of-care testing for SARS-CoV-2 could quickly identify which patients need to be isolated and improve flow for patients being admitted as an emergency to the hospital. We evaluated two diagnostic tests with shorter turnaround times, the Siemens Clinitest Lateral Flow (Siemens Healthineers AG, Erlangen, Germany) and the Simple AMplification-Based Assay (SAMBA)-2 PCR test against a standard laboratory PCR test. Methods We conducted a prospective diagnostic cohort study in a single English emergency department. Adult participants underwent three swabs: the Siemens Clinitest Lateral Flow Test, the SAMBA-2 and a standard laboratory PCR test. Results A total of 212 participants were recruited. The sensitivity and specificity of the Siemens Clinitest Lateral Flow Test against the laboratory PCR test was 55.6% (95% CI 30.8-78.5) and 100% (95% CI 98.1-100) respectively. The sensitivity and specificity of the SAMBA-2 PCR test against the laboratory PCR test was 60.0% (95% CI 32.3-83.7) and 100% (95% CI 97.9-100) respectively. Conclusion Neither the Siemens Clinitest Lateral Flow Test nor the SAMBA-2 PCR test demonstrated sufficient sensitivity to rule out active SARS-CoV-2 infection. Both tests demonstrated high specificity.

Keywords: covid-19; emergency department; pcr test; samba-2; siemens clinitest.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. Recruitment of Participants

References

    1. Siemens. CLINITEST® Rapid COVID-19 Antigen Test. [ Sep; 2021 ];https://www.siemens-healthineers.com/en-uk/point-of-care-testing/covid-1... 2020
    1. Handling and accuracy of four rapid antigen tests for the diagnosis of SARS-CoV-2 compared to RT-qPCR. Olearo F, Nörz D, Heinrich F, et al. J Clin Virol. 2021;137:104782. - PMC - PubMed
    1. Point-of-care evaluation of a rapid antigen test (CLINITESTⓇ Rapid COVID-19 Antigen Test) for diagnosis of SARS-CoV-2 infection in symptomatic and asymptomatic individuals. Torres I, Poujois S, Albert E, Álvarez G, Colomina J, Navarro D. J Infect. 2021;82:11–12. - PMC - PubMed
    1. Performance evaluation of the SAMBA II SARS-CoV-2 test for point-of-care detection of SARS-CoV-2. Assennato SM, Ritchie AV, Nadala C, et al. J Clin Microbiol. 2020;59:0. - PMC - PubMed
    1. WHO. Advice on the use of point-of-care immunodiagnostic tests for COVID-19. [ Sep; 2021 ];https://www.who.int/news-room/commentaries/detail/advice-on-the-use-of-p... WHO. 2020

LinkOut - more resources