Background: Estimating cause-related mortality among the dead is not common, yet for clinical and public health purposes, a lot can be learnt from the dead. HIV/AIDS accounted for the third most frequent cause of deaths in Kenya; 39.7 deaths per 100,000 population in 2019. OraQuick Rapid HIV-1/2 has previously been validated on oral fluid and implemented as a screening assay for HIV self-testing in Kenya among living subjects. We assessed the feasibility and diagnostic accuracy of OraQuick Rapid HIV-1/2 for HIV screening among decedents.
Methods: Trained morticians collected oral fluid from 132 preembalmed and postembalmed decedents aged >18 months at Jaramogi Oginga Odinga Teaching and Referral Hospital mortuary in western Kenya and tested for HIV using OraQuick Rapid HIV-1/2. Test results were compared with those obtained using the national HIV Testing Services algorithm on matched preembalming whole blood specimens as a gold standard (Determine HIV and First Response HIV 1-2-O). We calculated positive predictive values, negative predictive values, area under the curve, and sensitivity and specificity of OraQuick Rapid HIV-1/2 compared with the national HTS algorithm.
Results: OraQuick Rapid HIV-1/2 had similar sensitivity of 92.6% [95% confidence interval (CI): 75.7 to 99.1] on preembalmed and postembalmed samples compared with the gold standard. Specificity was 97.1% (95% CI: 91.9 to 99.4) and 95.2% (95% CI: 89.2 to 98.4) preembalming and postembalming, respectively. Preembalming and postembalming positive predictive value was 89.3% (95% CI: 71.8 to 97.7) and 83.3% (95% CI: 65.3 to 94.4), respectively. The area under the curve preembalming and postembalming was 94.9% (95% CI: 89.6 to 100) and 93.9% (95% CI: 88.5 to 99.4), respectively.
Conclusions: The study showed a relatively high-performance sensitivity and specificity of OraQuick Rapid HIV-1/2 test among decedents, similar to those observed among living subjects. OraQuick Rapid HIV-1/2 presents a convenient and less invasive screening test for surveillance of HIV among decedents within a mortuary setting.
Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc.
Conflict of interest statement
The authors have no conflicts of interest to disclose.
Figures
References
-
- UNAIDS. UNAIDS DATA, 2008: UNAIDS; 2019. Available at: https://www.unaids.org/sites/default/files/media_asset/2019-UNAIDS-data_....
-
- National AIDS and STI Control Programme (NASCOP). Preliminary KENPHIA 2018 Report. Nairobi: NASCOP; 2020.
-
- AIDSInfo. Global data on HIV Epidemiology and Response. UNICEF Kenya Country Office Annual Report 2019; Available at: https://www.unicef.org/media/90381/file/Kenya-2019-COAR.pdf.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical