Abstract
The administration of dry anesthetic gases for ventilation lasting more than 1 h leads to morphological changes of the tracheobronchial epithelium that may cause postoperative pulmonary complications. Therefore, additional humidification is suggested for ventilation during anesthesia, particularly when using semiopen breathing systems. Recommendations concerning the use of semiclosed systems are controversial: previous studies have shown sufficient humidification on the one hand, and insufficient water content in the inspired air on the other hand. In this study, comparative humidity measurements in a semiopen and a semiclosed system were carried out during anesthesia and mechanical ventilation. We particularly wanted to find out whether placement of the fresh gas inlet into the circle before or behind the soda lime canister influences the humidity of the inspired gas. In addition, we tested three types of "heat and moisture exchanges"--Engström "Edith", Siemens "Servo Humidifier", and Portex "Humid Vent". A total of 58 patients between 23 and 78 years of age were studied. They were divided into three groups. Group I: In 10 patients comparative humidity measurements were carried out using both a semiopen and a semiclosed system. Group II: The time course of water saturation during a 3-h period was determined in 10 patients ventilated with a semiopen and 8 patients ventilated with a semiclosed circle system. Group III: In 20 patients we tested the effect of "heat and moisture exchangers". All patients were intubated and ventilated with the Spiromat 656 and the Circle System 8 (Drger) that made ventilation in both a semiclosed and a semiopen system possible. The humidity measurements were carried out using a psychometric method.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.Crit Care Med. 1994 Nov;22(11):1871-6. Crit Care Med. 1994. PMID: 7956294 Clinical Trial.
-
[Humidification and heating of anesthetic gases during pediatric anesthesia using the Cicero Anesthesia Workstation].Anaesthesist. 1992 Sep;41(9):534-8. Anaesthesist. 1992. PMID: 1416008 German.
-
[Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].Anasthesiol Intensivmed Notfallmed Schmerzther. 1998 May;33(5):300-5. doi: 10.1055/s-2007-994253. Anasthesiol Intensivmed Notfallmed Schmerzther. 1998. PMID: 9645289 Clinical Trial. German.
-
[Anesthesia systems].Anaesthesist. 1987 Aug;36(8):393-9. Anaesthesist. 1987. PMID: 3310726 Review. German.
-
Humidification during anesthesia.Respir Care Clin N Am. 1998 Jun;4(2):281-99. Respir Care Clin N Am. 1998. PMID: 9648187 Review.