Comparing the patient experience between a novel 360° gamma camera (VERITON-CT) and a conventional dual head gamma camera

Affiliations

Comparing the patient experience between a novel 360° gamma camera (VERITON-CT) and a conventional dual head gamma camera

Hend Komber et al. J Nucl Med Technol. .

Abstract

Aims: To explore whether the novel 360° gamma camera design of VERITON-CT adversely affects the rate of scan non-completion due to claustrophobia or other patient experience factors, when compared to a standard dual-headed gamma camera. Methods: Single centre prospective study of all nuclear medicine studies on either of two gamma cameras; the VERITON-CT (Spectrum Dynamics Medical) and Discovery NM/CT 670 (GE Healthcare). It was recorded whether the patient had completed the scan as protocoled or, due to claustrophobia, had a shortened scan or no scan. The patients were also offered a patient experience questionnaire, with domains of comfort, scan time, scan noise and claustrophobia assessed using a five-point Likert scale. Results: Over a four-month period, there were 296 patients scanned on the Discovery scanner and 274 patients scanned on the VERITON-CT scanner. There was a scan non-completion rate, due to claustrophobia, of 1.35 % for the Discovery and 1.46 % for the VERITON-CT scanner. 354/570 (62%) of all patients involved returned their questionnaires. There was no statistical difference between the responses for comfort, scan time, scan noise and feelings of claustrophobia. Conclusion: The study provides evidence that the novel 360° gamma camera design of VERITON-CT does not lead to a significantly increased scan failure rate due to claustrophobia and there is no change in the subjective experience for patients.

Keywords: Camera-Based High Energy Imaging; Claustrophobia; Discovery 670; Gamma Camera; Patient Experience; Quality Assurance; SPECT/CT; VERITON-CT.

PubMed Disclaimer

Figures

None
Graphical abstract
FIGURE 1.
FIGURE 1.
Conventional Anger camera (left) vs. Veriton-CT scanner (right), with 360° detector design. (Courtesy of Spectrum Dynamics Medical.)
FIGURE 2.
FIGURE 2.
Questionnaire on experience of nuclear imaging patient.
FIGURE 3.
FIGURE 3.
Spread of survey responses across 4 experience factors.

References

    1. Van den Wyngaert T, Elvas F, De Schepper S, Kennedy JA, Israel O. SPECT/CT: standing on the shoulders of giants, it is time to reach for the sky! J Nucl Med. 2020;61:1284–1291. - PubMed
    1. Liu CJ, Cheng JS, Chen YC, Huang YH, Yen RF. A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation. Ann Nucl Med. 2015;29:342–350. - PubMed
    1. Imbert L, Chevalier E, Claudin M, et al. . A one-shot whole-body bone SPECT may be recorded in less than 20 minutes with the high-sensitivity Veriton® CZT-camera [abstract]. J Nucl Med. 2019;60(suppl 1):1288.
    1. Chou IJ, Tench CR, Gowland P, et al. . Subjective discomfort in children receiving 3 T MRI and experienced adults’ perspective on children’s tolerability of 7 T: a cross-sectional questionnaire survey. BMJ Open. 2014;4:e006094. - PMC - PubMed
    1. Dyrberg E, Larsen EL, Hendel HW, Thomsen HS. Diagnostic bone imaging in patients with prostate cancer: patient experience and acceptance of NaF-PET/CT, choline-PET/CT, whole-body MRI, and bone SPECT/CT. Acta Radiol. 2018;59:1119–1125. - PubMed

LinkOut - more resources