. 2022 Sep;100(6):654-664.
doi: 10.1111/aos.15063. Epub 2021 Nov 8.

Dynamic volume-rendered optical coherence tomography pupillometry

Affiliations
Free article

Dynamic volume-rendered optical coherence tomography pupillometry

Peter M Maloca et al. Acta Ophthalmol. 2022 Sep.
Free article

Abstract

Purpose: To assess intrapupillary space (IPS) changes in healthy subjects with regard to decreased iris motility in patients with pseudoexfoliation glaucoma (PEXG) or non-arteritic anterior ischaemic optic neuropathy (NAION) in a feasibility study in a clinical environment.

Methods: Scotopic and photopic IPS measurements using three-dimensionally rendered swept-source optical coherence tomography (SS-OCT) data were obtained and compared for all subjects. Intrapupillary space (IPS) parameters were evaluated such as absolute volumetric differences, relative light response for volumetric ratios and pupillary ejection fraction (PEF) for functional contraction measurements.

Results: From a total of 122 IPS from 66 subjects, 106 IPS were eligible for comparison providing values for 72 normal, 30 PEXG and 4 NAION eyes. In healthy, PEXG and NAION subjects, scotopic overall mean IPS was 8.90, 3.45 and 4.16 mm3 , and photopic overall mean IPS was 0.87, 0.74 and 1.13 mm3 , respectively. Three-dimensional contractility showed a mean absolute difference of 8.03 mm3 for normals (defined as 100% contractility), 2.72 mm3 for PEXG (33.88% of normal) and 3.03 mm3 for NAION (38.50% of normal) with a relative light response ratio between scotopic and photopic volumes of 10.26 (100%), 4.69 (45.70%) and 3.67 (35.78%), respectively. Pupillary ejection fraction (PEF) showed a contractile pupillary emptying of 88.11% for normals, 76.92% for PEXG and 70.91% for NAION patients.

Conclusion: This 3D pupillometry OCT assessment allows for quantitative measurements of pupil function, contractility and response to light. More specifically, PEF is presented as a potential (neuro)-pupillary outcome measure that could be useful in the monitoring of ophthalmic disorders that affect pupillary function.

Keywords: contractility; non-arteritic anterior ischaemic optic neuropathy; optical coherence tomography; pseudoexfoliation glaucoma; pupillary ejection fraction.

PubMed Disclaimer

References

    1. Abouali O, Modareszadeh A, Ghaffarieh A & Tu J (2012): Investigation of saccadic eye movement effects on the fluid dynamic in the anterior chamber. J Biomech Eng 134: 021002.
    1. Akman A, Yilmaz G, Oto S & Akova YA (2004): Comparison of various pupil dilatation methods for phacoemulsification in eyes with a small pupil secondary to pseudoexfoliation. Ophthalmology 111: 1693-1698.
    1. Aoki T, Kitazawa K, Inatomi T et al. (2020): Risk factors for corneal endothelial cell loss in patients with pseudoexfoliation syndrome. Sci Rep 10: 7260.
    1. Aptel F & Denis P (2010): Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis. Ophthalmology 117: 3-10.
    1. Atchison DA, Girgenti CC, Campbell GM, Dodds JP, Byrnes TM & Zele AJ (2011): Influence of field size on pupil diameter under photopic and mesopic light levels. Clin Exp Optom 94: 545-548.

LinkOut - more resources