Cavitas electrochemical sensors for the direct determination of salivary thiocyanate levels
- PMID: 34755233
- DOI: 10.1007/s00604-021-05067-7
Cavitas electrochemical sensors for the direct determination of salivary thiocyanate levels
Abstract
Noninvasive diagnosis using salivary samples to detect thiocyanate provides vital information on individual health. This article demonstrates the first example of a wearable sensing device to noninvasively assess thiocyanate levels. The customized screen-printed electrode system is integrated into a form of a mouthguard squarewave-voltammetric sensor toward the convenient and fast detection of the salivary biomarker within 15 s. The sensor with a protective film to mitigate the effect of biofouling offers high sensitivity and selectivity toward the detection of thiocyanate ions. Partial least square regression is applied to analyze the high-order squarewave-voltammetric data over the applied potential range of 0-1.75 V vs Ag/AgCl and quantify the thiocyanate concentration in a complex matrix. The mouthguard sensor operating under physiological conditions can monitor a wide range of thiocyanate (up to 11 mM) with a low detection limit of 30 µM. The demonstration introduces a unique approach, that obviates the requirement for blood sampling, to study thiocyanate levels of healthy people, cigarette smokers, or people with other health conditions. It is envisioned that the new cavitas device possesses a substantial promise for diverse biomedical diagnosis applications.
Keywords: Saliva; Screen-printed sensors; Squarewave voltammetry; Smokers; Thiocyanate; Wearable sensors.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.
References
-
- Sempionatto JR, Jeerapan I, Krishnan S, Wang J (2020) Wearable chemical sensors: emerging systems for on-body analytical chemistry. Anal Chem 92:378–396. https://doi.org/10.1021/acs.analchem.9b04668 - DOI - PubMed
-
- Pungjunun K, Yakoh A, Chaiyo S, Praphairaksit N, Siangproh W, Kalcher K, Chailapakul O (2021) Laser engraved microapillary pump paper-based microfluidic device for colorimetric and electrochemical detection of salivary thiocyanate. Microchim Acta 188:140. https://doi.org/10.1007/s00604-021-04793-2 - DOI
-
- Ponnaiah SK, Prakash P, Vellaichamy B, Paulmony T, Selvanathan R (2018) Picomolar-level electrochemical detection of thiocyanate in the saliva samples of smokers and non-smokers of tobacco using carbon dots doped Fe3O4 nanocomposite embedded on g-C3N4 nanosheets. Electrochim Acta 283:914–921. https://doi.org/10.1016/j.electacta.2018.07.012 - DOI
-
- Yang Y, Song Y, Bo X, Min J, Pak OS, Zhu L, Wang M, Tu J, Kogan A, Zhang H, Hsiai TK, Li Z, Gao W (2020) A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat. Nat Biotechnol 38:217–224. https://doi.org/10.1038/s41587-019-0321-x - DOI - PubMed
-
- Mani V, Beduk T, Khushaim W, Ceylan AE, Timur S, Wolfbeis OS, Salama KN (2021) Electrochemical sensors targeting salivary biomarkers: a comprehensive review. TrAC Trends Anal Chem 135:116164. https://doi.org/10.1016/j.trac.2020.116164 - DOI