Accuracy of Newer Generation IOL Power Calculation Formulas in Eyes With High Axial Myopia
- PMID: 34756144
- DOI: 10.3928/1081597X-20210712-08
Accuracy of Newer Generation IOL Power Calculation Formulas in Eyes With High Axial Myopia
Abstract
Purpose: To compare the accuracy of the Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Kane, and SRK/T formulas for intraocular lens power calculation in patients with high axial myopia.
Methods: In this retrospective study, 175 eyes (175 patients) that underwent uneventful cataract surgery were enrolled. According to the axial length (AL), the eyes were divided into long AL (26 ⩽ AL < 28 mm), super long AL (28 ⩽ AL < 30 mm), and extremely long AL (⩾ 30 mm). The mean absolute prediction errors (MAE) 3 months postoperatively and the percentage of eyes within different prediction error were compared, followed by subgroup analysis.
Results: The MAE and percentage of eyes within ±0.50 diopters (D) of the five formulas were as follows: Barrett Universal II (0.342, 74.9%), EVO 2.0 (0.314, 82.3%), Haigis (0.336, 74.9%), Kane (0.318, 78.9%), and SRK/T (0.398, 69.7%) (P = .552 and .071, respectively). Although no significant difference was found among the five formulas in the super and extremely long AL groups (P = .792 and .227, respectively), the EVO 2.0 formula achieved the highest accuracy (88.9%, 72 of 81) in the long AL group (P = .049). Moreover, the accuracy of the EVO 2.0 and Haigis formulas was stable, regardless of AL. The SRK/T formula showed a negative trend in the long and super long AL groups, whereas the Barrett Universal II, Kane, and SRK/T formulas showed positive trends in the extremely long AL group.
Conclusions: Overall, the EVO 2.0 and Kane formulas achieved better results in patients with high axial myopia, whereas the other three formulas showed slightly poor outcomes. [J Refract Surg. 2021;37(11):754-758.].
Similar articles
-
Comparison of IOL Power Calculation Formulas for a Trifocal IOL in Eyes With High Myopia.J Refract Surg. 2021 Aug;37(8):538-544. doi: 10.3928/1081597X-20210506-01. Epub 2021 Aug 1. J Refract Surg. 2021. PMID: 34388073
-
Comparison of accuracy of intraocular lens power calculation for eyes with an axial length greater than 29.0 mm.Int Ophthalmol. 2022 Jul;42(7):2029-2038. doi: 10.1007/s10792-021-02194-1. Epub 2022 May 10. Int Ophthalmol. 2022. PMID: 35536455 Free PMC article.
-
Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients.Graefes Arch Clin Exp Ophthalmol. 2023 Apr;261(4):1019-1027. doi: 10.1007/s00417-022-05896-z. Epub 2022 Nov 17. Graefes Arch Clin Exp Ophthalmol. 2023. PMID: 36385570
-
Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis.Clin Exp Ophthalmol. 2018 Sep;46(7):738-749. doi: 10.1111/ceo.13184. Epub 2018 Mar 24. Clin Exp Ophthalmol. 2018. PMID: 29498180
-
Network Meta-analysis of Intraocular Lens Power Calculation Formula Accuracy in 1016 Eyes With Long Axial Length.Am J Ophthalmol. 2024 Jan;257:178-186. doi: 10.1016/j.ajo.2023.09.009. Epub 2023 Sep 17. Am J Ophthalmol. 2024. PMID: 37726043
Cited by
-
Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens.BMC Ophthalmol. 2024 Aug 5;24(1):326. doi: 10.1186/s12886-024-03605-4. BMC Ophthalmol. 2024. PMID: 39103785 Free PMC article.
-
The Postoperative Visual and Refractive Outcomes of Trifocal and Extended Depth-of-Focus Intraocular Lenses in Patients with Different Biometric Characteristics.Diagnostics (Basel). 2024 Aug 7;14(16):1717. doi: 10.3390/diagnostics14161717. Diagnostics (Basel). 2024. PMID: 39202205 Free PMC article.
-
Influence of Ocular Biometry Parameters on the Predictive Accuracy of IOL Power Formulas in Patients with High Myopia.Ophthalmol Ther. 2024 Jan;13(1):435-448. doi: 10.1007/s40123-023-00856-0. Epub 2023 Dec 4. Ophthalmol Ther. 2024. PMID: 38048035 Free PMC article.
-
Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes.Graefes Arch Clin Exp Ophthalmol. 2024 Nov;262(11):3619-3628. doi: 10.1007/s00417-024-06506-w. Epub 2024 May 17. Graefes Arch Clin Exp Ophthalmol. 2024. PMID: 38758376
-
Comparing the accuracy of intraocular lens power calculation formulas using artificial intelligence and traditional formulas in highly myopic patients: a meta-analysis.Int Ophthalmol. 2024 Jun 21;44(1):242. doi: 10.1007/s10792-024-03227-1. Int Ophthalmol. 2024. PMID: 38904666
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials