Clinical utility of 3D magnetic resonance elastography in patients with biliary obstruction
- PMID: 34791513
- DOI: 10.1007/s00330-021-08295-w
Clinical utility of 3D magnetic resonance elastography in patients with biliary obstruction
Abstract
Objectives: Three-dimensional magnetic resonance elastography (3D-MRE) allows for multiparametric modeling of both elastic and viscous tissue characteristics. Our aim was to compare 3D-MRE with conventional liver shear stiffness assessment in gauging obstructive jaundice (OJ), predicting the adequacy of biliary decompression after drainage, and discriminating OJ from liver fibrosis.
Methods: Patients with no histories of liver disease (n = 201) were studied in retrospect, grouped by bilirubin levels as no jaundice (NJ ≤ 2 mg/dL; n = 75), mild OJ (>2 mg/dL and ≤ 4 mg/dL; n = 56), and severe OJ (> 4 mg/dL; n = 70). For comparison, another 75 patients with chronic hepatitis B and C infections and histologically proven liver fibrosis were similarly analyzed. Each patient underwent spin-echo echo-planar-imaging MRE at 60 Hz with 3D wave postprocessing. Logistic regression and ordinary regression models were used to compare the 3D-MRE model with liver shear stiffness.
Results: Liver shear stiffness, loss modulus, and damping ratio were incorporated into a 3D-MRE model, which significantly outperformed shear stiffness in predicting OJ severity (accuracy: 0.801 vs 0.672; p < 0.001). Both the 3D-MRE model and liver shear stiffness performed equally well in predicting the outcome of biliary drainage procedure (C-statistics: 0.852 vs 0.847; p = 0.48). The 3D-MRE model also demonstrated significantly better C-statistics than that of liver shear stiffness in discriminating mild OJ from F1-F2 liver fibrosis (0.765 vs 0.641; p = 0.005) and severe OJ from F3-F4 liver fibrosis (0.750 vs 0.635; p = 0.031).
Conclusions: 3D-MRE is an innovative imaging method for gauging OJ severity, predicting the outcome of biliary drainage procedure, and discriminating OJ from liver fibrosis.
Key points: • 3D-MR elastography achieved promising results for predicting the severity of obstructive jaundice. • Advanced parameters of 3D-MR elastography demonstrated significantly better performance than that of shear stiffness of 2D-MR elastography in discriminating obstructive jaundice from liver fibrosis caused by chronic hepatitis B/C. • Both 3D-MR elastography and 2D-MR elastography were equivalent in predicting the outcome of biliary drainage procedure.
Keywords: Biomarkers; Elasticity imaging techniques; Jaundice, obstructive; Magnetic resonance imaging.
© 2021. “The Author(s) under exclusive licence to European Society of Radiology.
References
-
- Venkatesh SK, Wells ML, Miller FH et al (2018) Magnetic resonance elastography: beyond liver fibrosis-a case-based pictorial review. Abdom Radiol (NY) 43(7):1590–1611 - DOI
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources