Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Dec 15:161:70-75.
doi: 10.1016/j.amjcard.2021.08.062.

Clinical and Hemodynamic Effects of Percutaneous Edge-to-Edge Mitral Valve Repair in Atrial Versus Ventricular Functional Mitral Regurgitation

Affiliations
Free article

Clinical and Hemodynamic Effects of Percutaneous Edge-to-Edge Mitral Valve Repair in Atrial Versus Ventricular Functional Mitral Regurgitation

Marc J Claeys et al. Am J Cardiol. .
Free article

Abstract

The present study aims to assess the clinical and hemodynamic impact of percutaneous edge-to-edge mitral valve repair with MitraClip in patients with atrial functional mitral regurgitation (A-FMR) compared with ventricular functional mitral regurgitation (V-FMR). Mitral regurgitation (MR) grade, functional status (New York Heart Association class), and major adverse cardiac events (MACE; all-cause mortality or hospitalization for heart failure) were evaluated in 52 patients with A-FMR and in 307 patients with V-FMR. In 56 patients, hemodynamic assessment during exercise echocardiography was performed before and 6 months after intervention. MR reduction after MitraClip implantation was noninferior in A-FMR compared with V-FMR (MR grade ≤2 at 6 months in 94% vs 82%, respectively, p <0.001 for noninferiority) and was associated with improvement of functional status (New York Heart Association class ≤2 at 6 months in 90% vs 80%, respectively, p = 0.2). Hemodynamic assessment revealed that cardiac output at 6 months was higher in A-FMR at rest (5.1 ± 1.5 L/min vs 3.8 ± 1.5 L/min, p = 0.002) and during peak exercise (7.9 ± 2.4 L/min vs 6.1 ± 2.1 L/min, p = 0.02). In addition, the reduction in systolic pulmonary artery pressure at rest was more pronounced in A-FMR: Δ SPAP -13.1 ± 15.1 mm Hg versus -2.2 ± 13.3 mm Hg (p = 0.03). MACE rate at follow-up was significantly lower in A-FMR versus V-FMR, with an adjusted odds ratio of 0.46 (95% confidence interval 0.24 to 0.88), which was caused by a reduction in hospitalization for heart failure. In conclusion, percutaneous edge-to-edge mitral valve repair with MitraClip is at least as effective in A-FMR as in V-FMR in reducing MR. However, the hemodynamic improvement and reduction of MACE were significantly better in A-FMR.

PubMed Disclaimer

Conflict of interest statement

Disclosures M. Claeys has received honoraria fees (<10,000 euro) from Abbott company. The remaining authors have nothing to disclose.

Publication types

MeSH terms

LinkOut - more resources