Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2022 May;269(5):2338-2345.
doi: 10.1007/s00415-021-10903-0. Epub 2021 Nov 20.

The efficacy and safety of insertable cardiac monitor on atrial fibrillation detection in patients with ischemic stroke: a systematic review and meta-analysis

Affiliations
Meta-Analysis

The efficacy and safety of insertable cardiac monitor on atrial fibrillation detection in patients with ischemic stroke: a systematic review and meta-analysis

Xin Tan et al. J Neurol. 2022 May.

Abstract

Atrial fibrillation (AF) leads to a high risk of recurrent stroke, and the insertable cardiac monitor (ICM), as a new kind of electrocardiographic monitoring device, has been proven to enhance the recognition rate of AF. The aim of this systematic review was to evaluate the efficacy and safety of the ICM use in AF detection of patients with stroke. We pooled 1233 patients from three randomized controlled trials (RCTs). The detection rate of AF was superior in the ICM group to that in the control group at 6 months (risk ratio [RR], 4.63; P < 0.0001; 95% confidence interval [CI], 2.17-9.90) and 12 months (RR, 5.04; P < 0.00001; 95% CI, 2.93 to 8.68). Patients in the ICM group had a higher rate of oral anticoagulant usage (RR, 2.76; P < 0.00001; 95% CI, 1.89-4.02). However, there was no difference in the time to first detection of AF within 12 months (mean difference, - 8.28; P = 0.82; 95% CI, - 77.84-61.28) or the rate of recurrent ischemic stroke or transient ischemic attack (RR, 0.88; P = 0.51; 95% CI, 0.60-1.28) between the ICM and control groups. In addition, the ICM group experienced more adverse events than the control group within 12 months (RR, 4.42; P = 0.002; 95% CI, 1.69-11.55). To conclude, the sensitivity of ICM is superior to that of conventional external cardiac monitoring. Reducing adverse reactions will be a new development direction of ICM.

Keywords: Atrial fibrillation; Cardiac monitoring; Insertable cardiac monitor; Ischemic stroke; Systematic review.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Feigin VL et al (2021) Global, regional, and national burden of stroke and its risk factors, 1990–2019: a systematic analysis for the global burden of disease study 2019. Lancet Neurol 20(10):795–820. https://doi.org/10.1016/s1474-4422(21)00252-0 - DOI
    1. Freedman B, Potpara TS, Lip GY (2016) Stroke prevention in atrial fibrillation. Lancet 388(10046):806–817. https://doi.org/10.1016/s0140-6736(16)31257-0 - DOI
    1. Virani SS, Alonso A, Benjamin EJ, Bittencourt MS, Callaway CW, Carson AP, Chamberlain AM, Chang AR, Cheng S, Delling FN et al (2020) Heart disease and stroke statistics-2020 update: a report from the american heart association. Circulation 141(9):e139–e596. https://doi.org/10.1161/cir.0000000000000757 - DOI
    1. Kimura K, Minematsu K, Yamaguchi T (2005) Atrial fibrillation as a predictive factor for severe stroke and early death in 15,831 patients with acute ischaemic stroke. J Neurol Neurosurg Psychiatry 76(5):679–683. https://doi.org/10.1136/jnnp.2004.048827 - DOI
    1. (1993) Secondary prevention in non-rheumatic atrial fibrillation after transient ischaemic attack or minor stroke. EAFT (European Atrial Fibrillation Trial) Study Group. Lancet 342(8882):1255–1262

MeSH terms

LinkOut - more resources