. 2021 Nov 22;11(1):22683.
doi: 10.1038/s41598-021-02111-7.

CinE caRdiac magneTic resonAnce to predIct veNTricular arrhYthmia (CERTAINTY)

Affiliations

CinE caRdiac magneTic resonAnce to predIct veNTricular arrhYthmia (CERTAINTY)

Julian Krebs et al. Sci Rep. .

Abstract

Better models to identify individuals at low risk of ventricular arrhythmia (VA) are needed for implantable cardioverter-defibrillator (ICD) candidates to mitigate the risk of ICD-related complications. We designed the CERTAINTY study (CinE caRdiac magneTic resonAnce to predIct veNTricular arrhYthmia) with deep learning for VA risk prediction from cine cardiac magnetic resonance (CMR). Using a training cohort of primary prevention ICD recipients (n = 350, 97 women, median age 59 years, 178 ischemic cardiomyopathy) who underwent CMR immediately prior to ICD implantation, we developed two neural networks: Cine Fingerprint Extractor and Risk Predictor. The former extracts cardiac structure and function features from cine CMR in a form of cine fingerprint in a fully unsupervised fashion, and the latter takes in the cine fingerprint and outputs disease outcomes as a cine risk score. Patients with VA (n = 96) had a significantly higher cine risk score than those without VA. Multivariate analysis showed that the cine risk score was significantly associated with VA after adjusting for clinical characteristics, cardiac structure and function including CMR-derived scar extent. These findings indicate that non-contrast, cine CMR inherently contains features to improve VA risk prediction in primary prevention ICD candidates. We solicit participation from multiple centers for external validation.

PubMed Disclaimer

Conflict of interest statement

HA serves as a consultant to Siemens Healthineers. No other authors have competing interests.

Figures

Figure 1
Figure 1
Algorithm overview. (A) Cine fingerprint extractor. (B) Risk predictor. See text for details.
Figure 2
Figure 2
Survival prediction for each endpoint. (A) LV LGE gray zone. (B) LA maximum volume index, (C) LA total emptying fraction, (D) Cine risk score. The shaded area represents 95% confidence interval.
Figure 3
Figure 3
Survival prediction for each endpoint using multivariate Cox Proportional Hazards Regression models. (A) Cine risk score + LV LGE gray zone. (B) Cine risk score + LA maximum volume index. (C) Cine risk score + LA total emptying fraction. (D) LV LGE gray zone + LA maximum volume index + LA total emptying fraction. (E) Cine risk score + LV LGE gray zone + LA maximum volume index + LA total emptying fraction. The shaded area represents 95% confidence interval.

References

    1. Epstein AE, et al. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: A report of the American college of cardiology foundation/american heart association task force on practice guide. Circulation. 2013 doi: 10.1161/CIR.0b013e318276ce9b. - DOI - PubMed
    1. Sabbag A, et al. Contemporary rates of appropriate shock therapy in patients who receive implantable device therapy in a real-world setting: From the Israeli ICD Registry. Heart Rhythm. 2015;12:2426–2433. doi: 10.1016/j.hrthm.2015.08.020. - DOI - PubMed
    1. Prutkin JM, et al. Rates of and factors associated with infection in 200 909 medicare implantable cardioverter-defibrillator implants results from the national cardiovascular data registry. Circulation. 2014 doi: 10.1161/CIRCULATIONAHA.114.009081. - DOI - PubMed
    1. Moss AJ, et al. Reduction in inappropriate therapy and mortality through ICD programming. N. Engl. J. Med. 2012 doi: 10.1056/NEJMoa1211107. - DOI - PubMed
    1. Poole JE, et al. Prognostic importance of defibrillator shocks in patients with heart failure. N. Engl. J. Med. 2008 doi: 10.1056/NEJMoa071098. - DOI - PMC - PubMed

Publication types