Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation
- PMID: 34814700
- DOI: 10.1161/CIRCULATIONAHA.121.056301
Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation
Abstract
Background: Smaller randomized studies have reported conflicting results regarding the optimal electrode position for cardioverting atrial fibrillation. However, anterior-posterior electrode positioning is widely used as a standard and believed to be superior to anterior-lateral electrode positioning. Therefore, we aimed to compare anterior-lateral and anterior-posterior electrode positioning for cardioverting atrial fibrillation in a multicenter randomized trial.
Methods: In this multicenter, investigator-initiated, open-label trial, we randomly assigned patients with atrial fibrillation scheduled for elective cardioversion to either anterior-lateral or anterior-posterior electrode positioning. The primary outcome was the proportion of patients in sinus rhythm after the first shock. The secondary outcome was the proportion of patients in sinus rhythm after up to 4 shocks escalating to maximum energy. Safety outcomes were any cases of arrhythmia during or after cardioversion, skin redness, and patient-reported periprocedural pain.
Results: We randomized 468 patients. The primary outcome occurred in 126 patients (54%) assigned to the anterior-lateral electrode position and in 77 patients (33%) assigned to the anterior-posterior electrode position (risk difference, 22 percentage points [95% CI, 13-30]; P<0.001). The number of patients in sinus rhythm after the final cardioversion shock was 216 (93%) assigned to anterior-lateral electrode positioning and 200 (85%) assigned to anterior-posterior electrode positioning (risk difference, 7 percentage points [95% CI, 2-12]). There were no significant differences between groups in any safety outcomes.
Conclusions: Anterior-lateral electrode positioning was more effective than anterior-posterior electrode positioning for biphasic cardioversion of atrial fibrillation. There were no significant differences in any safety outcome. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03817372.
Keywords: atrial fibrillation; electric countershock; electrodes.
Comment in
-
Response to Letters Regarding Article, "Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation".Circulation. 2022 May 24;145(21):e1057-e1058. doi: 10.1161/CIRCULATIONAHA.122.059689. Epub 2022 May 23. Circulation. 2022. PMID: 35605031 No abstract available.
-
Letter by Ibrahim et al Regarding Article, "Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation".Circulation. 2022 May 24;145(21):e1056. doi: 10.1161/CIRCULATIONAHA.122.059061. Epub 2022 May 23. Circulation. 2022. PMID: 35605033 No abstract available.
-
Letter by Maqsood et al Regarding Article, "Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation".Circulation. 2022 May 24;145(21):e1054-e1055. doi: 10.1161/CIRCULATIONAHA.121.058800. Epub 2022 May 23. Circulation. 2022. PMID: 35605034 No abstract available.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Medical