Scleral fixation of subluxated or dislocated multifocal and multifocal toric intraocular lenses
- PMID: 34817677
- DOI: 10.1007/s00417-021-05498-1
Scleral fixation of subluxated or dislocated multifocal and multifocal toric intraocular lenses
Abstract
Purpose: To evaluate the feasibility of scleral fixation of subluxated or dislocated multifocal/multifocal toric intraocular lenses (IOLs) to rescue the IOL and restore both near and far vision.
Method: A total of 18 eyes of 17 patients who underwent transscleral or intrascleral fixation of subluxated or dislocated multifocal or multifocal toric IOLs at 2.5 mm posterior to the limbus were enrolled. Preoperative uncorrected distance visual acuity (UDVA) and postoperative UDVA values were compared in this retrospective cross-sectional study. The postoperative corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA) at 40 cm, residual sphere, cylinder, spherical equivalent, and IOL centration were evaluated.
Results: The mean follow-up period was 4.0 ± 5.0 months. The mean preoperative UDVA was 0.73 ± 0.71 logMAR and the postoperative UDVA was 0.05 ± 0.10 logMAR, which was significantly improved relative to the preoperative UDVA. The mean postoperative CDVA was 0.00 ± 0.00 logMAR and the mean postoperative UNVA at 40 cm was 0.05 ± 0.07 logMAR. The mean postoperative residual sphere, cylinder, and spherical equivalent values were - 0.21 ± 0.41 D, - 0.29 ± 0.26 CD, and - 0.33 ± 0.39 D, respectively. Postoperative anterior segment photographs showed good centration of optics in all cases of single-piece foldable multifocal IOLs but a slight inferior decentration in one case of a three-piece multifocal IOL.
Conclusion: Scleral fixation of subluxated or dislocated multifocal and multifocal toric IOLs could be one of the treatment options to rescue subluxated or dislocated multifocal IOLs and restore both near and far vision.
Keywords: Dislocation; Intraocular lens; Multifocal; Subluxation; Transscleral fixation.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
References
-
- Pueringer SL, Hodge DO, Erie JC (2011) Risk of late intraocular lens dislocation after cataract surgery, 1980–2009: a population-based study. Am J Ophthalmol 152:618–623. https://doi.org/10.1016/j.ajo.2011.03.009 - DOI - PubMed - PMC
-
- Fan Q, Han X, Luo J, Cai L, Qiu X, Lu Y, Yang J (2021) Risk factors of intraocular lens dislocation following routine cataract surgery: a case-control study. Clin Exp Optom 104:510–517. https://doi.org/10.1080/08164622.2021.1878829 - DOI - PubMed
-
- Lorente R, de Rojas V, Vazquez de Parga P, Moreno C, Landaluce ML, Dominguez R, Lorente B (2010) Management of late spontaneous in-the-bag intraocular lens dislocation: Retrospective analysis of 45 cases. J Cataract Refract Surg 36:1270–1282. https://doi.org/10.1016/j.jcrs.2010.01.035 - DOI - PubMed
-
- Michaeli A, Soiberman U, Loewenstein A (2012) Outcome of iris fixation of subluxated intraocular lenses. Graefes Arch Clin Exp Ophthalmol 250:1327–1332. https://doi.org/10.1007/s00417-012-2057-x - DOI - PubMed
-
- Kim SS, Smiddy WE, Feuer W, Shi W (2008) Management of dislocated intraocular lenses. Ophthalmology 115:1699–1704. https://doi.org/10.1016/j.ophtha.2008.04.016 - DOI - PubMed
MeSH terms
Grants and funding
- 2018/TRC Research Grant of the Korea University Medicine and Korea Institute of Science and Technology
- K1625491/Korea University Ansan Hospital grant
- K1722121/Korea University Ansan Hospital grant
- K1811051/Korea University Ansan Hospital grant
- K1913161/Korea University Ansan Hospital grant
- K2010921/Korea University Ansan Hospital grant
- K1625491/Korea University grant
- K1722121/Korea University grant
- K1811051/Korea University grant
- K1913161/Korea University grant
- K2010921/Korea University grant
- Project Number: 9991007583/Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety)
- KMDF_PR_20200901_0296/Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety)
- 2020002960007/Korea Environment Industry & Technology Institute(KEITI) through Technology Development Project for Safety Management of Household Chemical Products, funded by Korea Ministry of Environment(MOE)
- NTIS-1485017544/Korea Environment Industry & Technology Institute(KEITI) through Technology Development Project for Safety Management of Household Chemical Products, funded by Korea Ministry of Environment(MOE)
- NRF-2021R1F1A1062017/National Research Foundation of Korea(NRF) grant funded by the Korea government(MSIT)
- S3127902/Technology development Program(S3127902) funded by the Ministry of SMEs and Startups(MSS, Korea)
LinkOut - more resources
Full Text Sources