Sensitivity of modern multislice CT for subarachnoid haemorrhage at incremental timepoints after headache onset: a 10-year analysis
- PMID: 34819306
- DOI: 10.1136/emermed-2020-211068
Sensitivity of modern multislice CT for subarachnoid haemorrhage at incremental timepoints after headache onset: a 10-year analysis
Abstract
Background: CT performed within 6 hours of headache onset is highly sensitive for the detection of subarachnoid haemorrhage (SAH). Beyond this time frame, if the CT is negative for blood, a lumbar puncture is often performed. Technology improvements in image noise reduction, resolution and motion artefact have enhanced the performance of multislice CT (MSCT) and may have further improved sensitivity. We aimed to describe how the sensitivity to SAH of modern MSCT changes with time from headache onset.
Methods: This was a retrospective analysis of electronic data collected as part of routine care among all patients presenting to Christchurch Hospital diagnosed with a SAH between 1 January 2008 and 31 December 2017. Patients were imaged with MSCT. The primary outcome was the proportion of patients with spontaneous aneurysmal SAH (identified via coding and confirmed by clinical and radiological records) that had a positive MSCT. The secondary outcome was the proportion of patients with any type of spontaneous SAH that had a positive MSCT.
Results: There were 347 patients with an SAH of whom 260 were aneurysmal SAH. MSCT identified 253 (97.3%) of all aneurysmal SAH and 332 (95.7%) of all SAH. The sensitivity of MSCT was 99.6% (95% CI 97.6 to 100) for aneurysmal SAH and 99.0% (95% CI 97.1 to 99.8) for all SAH at 48 hours after headache onset. At 24 hours after headache onset, the sensitivity for aneurysmal SAH was 100% (95% CI 98.3 to 100).
Conclusion: These data suggest that it may be possible to extend the timeframe from headache onset within which modern MSCT can be used to rule out aneurysmal SAH.
Keywords: emergency department; headache.
© Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.
Conflict of interest statement
Competing interests: None declared.
Similar articles
-
Can computed tomography angiography of the brain replace lumbar puncture in the evaluation of acute-onset headache after a negative noncontrast cranial computed tomography scan?Acad Emerg Med. 2010 Apr;17(4):444-51. doi: 10.1111/j.1553-2712.2010.00694.x. Acad Emerg Med. 2010. PMID: 20370785 Review.
-
Is there a role for lumbar puncture in early detection of subarachnoid hemorrhage after negative head CT?Intern Emerg Med. 2019 Apr;14(3):451-457. doi: 10.1007/s11739-018-1982-z. Epub 2018 Nov 24. Intern Emerg Med. 2019. PMID: 30474789
-
Determining the Diagnostic Utility of Lumbar Punctures in Computed Tomography Negative Suspected Subarachnoid Hemorrhage: A Systematic Review and Meta-analysis.World Neurosurg. 2021 Apr;148:e27-e34. doi: 10.1016/j.wneu.2020.11.152. Epub 2020 Dec 4. World Neurosurg. 2021. PMID: 33285333
-
Factors influencing time to computed tomography in emergency department patients with suspected subarachnoid haemorrhage.Emerg Med J. 2017 Jan;34(1):20-26. doi: 10.1136/emermed-2016-205785. Epub 2016 Sep 22. Emerg Med J. 2017. PMID: 27660386
-
Subarachnoid haemorrhage in the emergency department (SHED): a prospective, observational, multicentre cohort study.Emerg Med J. 2024 Nov 21;41(12):719-727. doi: 10.1136/emermed-2024-214068. Emerg Med J. 2024. PMID: 39266054
Cited by
-
GFAP and UCHL1 in Non-traumatic SAH: The Story thus Far. A Systematic Review of the Literature.CNS Neurol Disord Drug Targets. 2024;23(11):1328-1344. doi: 10.2174/0118715273276472231116104549. CNS Neurol Disord Drug Targets. 2024. PMID: 38213168
-
Diagnosis of subarachnoid haemorrhage: Systematic evaluation of CT head diagnostic accuracy and comparison with the 2022 NICE guidelines.Brain Spine. 2025 Feb 4;5:104200. doi: 10.1016/j.bas.2025.104200. eCollection 2025. Brain Spine. 2025. PMID: 40034490 Free PMC article.
-
High sensitivity in spontaneous intracranial hemorrhage detection from emergency head CT scans using ensemble-learning approach.Sci Rep. 2025 Aug 15;15(1):29919. doi: 10.1038/s41598-025-15835-7. Sci Rep. 2025. PMID: 40817352 Free PMC article.