The problem of valve prosthesis-patient mismatch
Abstract
Valve prostheses have played an important part in the past two decades in the management of patients with valvular heart disease. However, many of the devices used in valve replacement have introduced new clinical problems. This paper deals with some of the problems associated with valve replacement, including one not previously emphasized--valve prosthesis-patient mismatch, which may cause obstruction to ventricular outflow and/or inflow.
Similar articles
-
Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch after Mitral Valve Replacement: A Chinese Multicenter Clinical Study.Med Sci Monit. 2015 Aug 27;21:2542-6. doi: 10.12659/MSM.894044. Med Sci Monit. 2015. PMID: 26313311 Free PMC article.
-
Morphology, Clinicopathologic Correlations, and Mechanisms in Heart Valve Health and Disease.Cardiovasc Eng Technol. 2018 Jun;9(2):126-140. doi: 10.1007/s13239-016-0277-7. Epub 2016 Aug 8. Cardiovasc Eng Technol. 2018. PMID: 27502286 Review.
-
[Surgery of combined heart valve diseases by valve replacement, with special reference to the surgical plans in relation to organic or functional changes of the heart valve].Nihon Kyobu Geka Gakkai Zasshi. 1972 Mar;20(3):242-6. Nihon Kyobu Geka Gakkai Zasshi. 1972. PMID: 4676513 Japanese. No abstract available.
-
Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression.J Thorac Cardiovasc Surg. 2006 May;131(5):1036-44. doi: 10.1016/j.jtcvs.2005.10.028. J Thorac Cardiovasc Surg. 2006. PMID: 16678587
-
[Aortic valve replacement with a small valve prosthesis: a review of clinical and echocardiographic studies for impact of prosthesis-patient mismatch].Nihon Geka Gakkai Zasshi. 2007 Mar;108(2):59-63. Nihon Geka Gakkai Zasshi. 2007. PMID: 17405538 Review. Japanese.
Cited by
-
A 44-year experience of prosthetic heart valve implantation at Niigata University Hospital.J Artif Organs. 2012 Jun;15(2):109-16. doi: 10.1007/s10047-012-0637-5. Epub 2012 Apr 24. J Artif Organs. 2012. PMID: 22527975 Review.
-
Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?Heart. 2007 May;93(5):615-20. doi: 10.1136/hrt.2006.102764. Epub 2006 Dec 12. Heart. 2007. PMID: 17164480 Free PMC article.
-
Valve prosthesis--patient mismatch. A long-term sequela.Br Heart J. 1981 Mar;45(3):331-5. doi: 10.1136/hrt.45.3.331. Br Heart J. 1981. PMID: 6451234 Free PMC article.
-
Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch after Mitral Valve Replacement: A Chinese Multicenter Clinical Study.Med Sci Monit. 2015 Aug 27;21:2542-6. doi: 10.12659/MSM.894044. Med Sci Monit. 2015. PMID: 26313311 Free PMC article.
-
Prosthesis-Patient Mismatch: Current State of Evidence.Curr Cardiol Rep. 2025 Feb 10;27(1):49. doi: 10.1007/s11886-025-02212-z. Curr Cardiol Rep. 2025. PMID: 39928182 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources