Abstract
Background: Studies have suggested that automated synovial cell counting may overestimate the white blood cell (WBC) count, resulting in false positive tests when evaluating patients for the possibility of periprosthetic joint infection (PJI) after THA. However, associations between WBC counts high enough to mimic PJI in patients whose arthroplasties are not infected but rather are experiencing a variety of aseptic problems-including but not limited to metallosis, polyethylene wear, and recurrent dislocation-have not, to our knowledge, been adequately addressed. In addition, there is a lack of analyses about the polymorphonuclear percentage (PMN%) when assessed by automated analyzers in this context.
Questions/purposes: In the context of different indications for aseptic revision and different periprosthetic hip pathologic findings, we asked: (1) What were the synovial WBC count levels, and what proportion of values were above the 2018 International Consensus Meeting (ICM) cutoff (3000 cells/μL)? (2) What were the synovial PMN% levels, and what proportion of values were above the 2018 ICM (70%)?
Methods: We retrospectively studied the preoperative cell count analyses of synovial fluid in patients who underwent revision THA for aseptic reasons at our tertiary referral arthroplasty center between January 2015 and December 2017. We considered all revisions performed on patients during that time potentially eligible, and after prespecified exclusions were applied (exclusions mainly included 15% [197 of 1306] sporadic missing data and 12% [155 of 1306] insufficient synovial fluid obtained in the aspirate), a total of 702 patients undergoing revision THA for aseptic reasons remained for the final analysis. As far as we know, no patients underwent re-revision for PJI at a mean follow-up of 46 ± 11 months, which tends to confirm our impression that indeed these hips did not have PJI. Cell count analyses were conducted using an automated analyzer. Clinical findings, preoperative radiographs, and surgical reports--confirmed by available histologic results--were used to establish diagnoses. We evaluated these hips considering the recommendations of the 2018 ICM (WBC count of 3000 cells/μL and PMN% of 70%) to see what proportion of them would have been characterized as likely having PJI on basis of those cutoff values. The mean WBC count for the entire cohort was 2120 ± 2395 cells/μL. The mean PMN% for the entire cohort was 36% ± 22%.
Results: Compared with aseptic loosening and recurrent dislocation, polyethylene wear had the highest mean WBC count (3817 ± 3711 cells/μL; p < 0.001). Of the investigated periprosthetic conditions, wear-induced synovitis had the highest value (4464 ± 3620 cells/μL; p < 0.001). Considering the ICM threshold, polyethylene wear showed the highest proportion of WBC counts above 3000 cells/μL among the indications for aseptic revision (60% [25 of 42]; p < 0.001). Of the periprosthetic conditions, wear-induced synovitis showed the highest proportion beyond the ICM cutoff (60% [50 of 83]; p < 0.001). The mean PMN% for aseptic causes ranged between 28% and 44% without differences among them (p = 0.12). Patients with metallosis had the highest mean PMN% of the periprosthetic conditions investigated (45% ± 25%; p = 0.007). Regarding the ICM threshold, metallosis resulted in the largest proportion of patients with a PMN% above 70% (21% [10 of 47]; p = 0.003), and that for wear-induced synovitis was 6% (5 of 83; p = 0.42) and for osteolysis was 3% (1 of 33; p = 0.51). There were no differences among aseptic loosening, recurrent dislocation, and polyethylene wear in terms of the proportion above 70% among the aseptic revision causes.
Conclusion: Using automated cell counting, we found that WBC counts differ widely across indications for aseptic revision THA, and a high proportion of patients who underwent revision THA for aseptic reasons had WBC counts above the commonly used threshold of 3000 cells/μL. However, the PMN% was much less affected in several common indications for aseptic revision THA, making this measure more reliable for interpreting aspiration results using an automated analyzer. Based on the data distributions we observed, manual counting techniques might be considered in particular among patients with polyethylene wear, metal-on-metal bearing surfaces, or suspected metallosis. However, an elevated WBC count alone, observed using an automated analyzer in the context of polyethylene wear, should not be considered to be strongly suggestive of PJI, since that finding occurred so commonly among patients without infection.
Level of evidence: Level III, diagnostic study.
Copyright © 2021 by the Association of Bone and Joint Surgeons.
Conflict of interest statement
All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.
Figures



Comment in
-
CORR Insights®: What Is the Impact of Automated Synovial Cell Counting on Different Aseptic Causes and Periprosthetic Conditions Associated With Revision THA?Clin Orthop Relat Res. 2022 May 1;480(5):915-917. doi: 10.1097/CORR.0000000000002086. Epub 2021 Dec 7. Clin Orthop Relat Res. 2022. PMID: 34874342 Free PMC article. No abstract available.
Similar articles
-
Assessing the reliability of automated cell count analysis of synovial fluid in the setting of revision total knee arthroplasty.Arch Orthop Trauma Surg. 2024 Dec 12;145(1):25. doi: 10.1007/s00402-024-05652-4. Arch Orthop Trauma Surg. 2024. PMID: 39666043
-
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion?Clin Orthop Relat Res. 2015 Feb;473(2):498-505. doi: 10.1007/s11999-014-3902-5. Clin Orthop Relat Res. 2015. PMID: 25171935 Free PMC article.
-
Increased Synovial Inflammatory Markers in Aseptic Total Hip Arthroplasty Dislocation.J Arthroplasty. 2020 May;35(5):1412-1416. doi: 10.1016/j.arth.2019.12.034. Epub 2019 Dec 21. J Arthroplasty. 2020. PMID: 31948812
-
Diagnostic Accuracy of Serum, Synovial, and Tissue Testing for Chronic Periprosthetic Joint Infection After Hip and Knee Replacements: A Systematic Review.J Bone Joint Surg Am. 2019 Apr 3;101(7):635-649. doi: 10.2106/JBJS.18.00632. J Bone Joint Surg Am. 2019. PMID: 30946198
-
Low Reinfection Rates But a High Rate of Complications in THA for Infection Sequelae in Childhood: A Systematic Review.Clin Orthop Relat Res. 2021 May 1;479(5):1094-1108. doi: 10.1097/CORR.0000000000001607. Clin Orthop Relat Res. 2021. PMID: 33617159 Free PMC article.
Cited by
-
Assessing the reliability of automated cell count analysis of synovial fluid in the setting of revision total knee arthroplasty.Arch Orthop Trauma Surg. 2024 Dec 12;145(1):25. doi: 10.1007/s00402-024-05652-4. Arch Orthop Trauma Surg. 2024. PMID: 39666043
-
Timepoint of aspiration can impact diagnostic of PJI - synovial fluid analyses exhibit a high intraindividual variation in periprosthetic joint infections of the knee.Arch Orthop Trauma Surg. 2025 Apr 29;145(1):276. doi: 10.1007/s00402-025-05888-8. Arch Orthop Trauma Surg. 2025. PMID: 40299053 Free PMC article.
-
Synovial fluid fibrin degradation product can be used as a new auxiliary marker for periprosthetic joint infection diagnosis.Front Cell Infect Microbiol. 2025 May 2;15:1435970. doi: 10.3389/fcimb.2025.1435970. eCollection 2025. Front Cell Infect Microbiol. 2025. PMID: 40384983 Free PMC article.
-
Is a preoperative pathogen detection a prerequisite before undergoing one-stage exchange for prosthetic joint infection of the hip?Arch Orthop Trauma Surg. 2023 Jun;143(6):2823-2830. doi: 10.1007/s00402-022-04459-5. Epub 2022 May 4. Arch Orthop Trauma Surg. 2023. PMID: 35508548 Free PMC article.
-
Synovial fluid pH is as specific as synovial leukocyte count but less sensitive for the diagnosis of chronic prosthetic joint infection.J Orthop Traumatol. 2022 Nov 19;23(1):52. doi: 10.1186/s10195-022-00672-5. J Orthop Traumatol. 2022. PMID: 36402933 Free PMC article.
References
-
- Bäcker HC, Hardt S, Richards JT, Perka C, Janz V. Increased synovial inflammatory markers in aseptic total hip arthroplasty dislocation. J Arthroplasty. 2020;35:1412-1416. - PubMed
-
- Bauer TW, Bedair H, Screech JD, et al. Hip and knee section, diagnosis, laboratory tests: proceedings of International Consensus on Orthopedic Infections. J Arthroplasty. 2019;34:S351-S359. - PubMed
-
- Carli AV, Abdelbary H, Ahmadzai N, et al. Diagnostic accuracy of serum, synovial, and tissue testing for chronic periprosthetic joint infection after hip and knee replacements. J Bone Joint Surg Am. 2019;101:635-649. - PubMed
-
- Chalmers PN, Sporer SM, Levine BR. Correlation of aspiration results with aseptic loosening in total hip arthroplasty. J Arthroplasty. 2013;28:1671-1676. - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials