Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Feb;21(2):185-200.
doi: 10.1080/14760584.2022.2013821. Epub 2022 Jan 12.

Diagnostic accuracy of dried blood spots for serology of vaccine-preventable diseases: a systematic review

Affiliations

Diagnostic accuracy of dried blood spots for serology of vaccine-preventable diseases: a systematic review

Taylor A Holroyd et al. Expert Rev Vaccines. 2022 Feb.

Abstract

Introduction: Venous serum and plasma are optimal specimens for serological testing but may be logistically infeasible. Dried blood spots (DBS) are a feasible alternative, provided results are adequately sensitive and specific. We aimed to assess the diagnostic accuracy of DBS to measure IgG and IgM antibodies for vaccine-preventable diseases and compare test validity of DBS with venous blood.

Areas covered: In October 2020, we searched seven databases for peer-reviewed studies assessing the diagnostic accuracy of DBS specimens compared with serum in detecting antibodies to VPDs in humans. We extracted data and assessed risk of bias in all included studies. We calculated sensitivity and specificity with 95% confidence intervals for each index-reference test comparison. We narratively synthesized the identified evidence on diagnostic accuracy and blood collection and processing methods for DBS. Studies on measles and rubella IgG and IgM were the most frequently identified and reported generally high sensitivity and specificity.

Expert opinion: Lack of standardization in collection, storage, and testing methods limited systematic comparison across studies. Our findings indicate a need for additional validation studies on the diagnostic accuracy of DBS to expand their use in serological surveillance. We recommend practical considerations to improve standardized reporting for DBS validation studies.

Keywords: Capillary blood; diagnostic accuracy; dried blood spots; fingerprick; serology; serosurveillance; venous blood.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources