Chemiluminescence microarray immunoassay for multiple aminoglycoside antibiotics based on carbon nanotube-assisted signal amplification
- PMID: 34854960
- DOI: 10.1007/s00216-021-03809-3
Chemiluminescence microarray immunoassay for multiple aminoglycoside antibiotics based on carbon nanotube-assisted signal amplification
Abstract
The simultaneous determination of multiple analytes has been an urgent demand in screening of antibiotic residues in food products of animal origin due to its higher analysis efficiency. Five aminoglycoside antibiotics (AGAs) have been monitored in milk, including gentamicin (GEN), kanamycin (KAN), neomycin (NEO), and streptomycin/dihydrostreptomycin (STR/diSTR). A chemiluminescence microarray immunoassay (CLMIA) based on nitrocellulose membrane had been developed for the detection of multiple AGAs, which the LODs for STR, KAN, NEO, and GEN were 4.74 ng/mL, 4.97 ng/mL, 2.99 ng/mL, and 4.42 ng/mL respectively. To improve the sensitivity of immunoassay, single-well carbon tubes (SWCNTs) were utilized as solid support for loading horseradish peroxidase-labelled goat anti-mouse antibody to obtain the multi-enzyme particles. After the optimization of usage of multi-enzyme particles and antibodies, the enhanced CLMIA was established and evaluated. The LODs were 1.25 ng/mL for STR, 0.64 ng/mL for KAN, 0.38 ng/mL for GEN, and 0.39 ng/mL for NEO, which was improved by threefold, sevenfold, 11-fold, and sevenfold compared with the conventional CLMIA developed. These methods presented higher specificity and repeatability. Finally, the enhanced CLMIA based on CNT-assisted multi-enzyme particles was utilized to analyze twenty-five milk samples from local market and dairy farm, which all the results were below the LOD. The enhanced CLMIA showed the great application potential for the detection of multiple targets simultaneously and provided efficient tool for the screening of pollutants in food.
Keywords: Carbon tubes; Chemiluminescence; Microarray; Signal amplification.
© 2021. Springer-Verlag GmbH Germany, part of Springer Nature.
Similar articles
-
Detection of egg white allergy in children by specific IgE microarray chemiluminescence immunoassay.Clin Chim Acta. 2025 Jan 15;565:119966. doi: 10.1016/j.cca.2024.119966. Epub 2024 Sep 13. Clin Chim Acta. 2025. PMID: 39278524
-
Aptamer-based ellipsometric sensor for ultrasensitive determination of aminoglycoside group antibiotics from dairy products.J Sci Food Agric. 2020 Jun;100(8):3386-3393. doi: 10.1002/jsfa.10372. Epub 2020 Apr 1. J Sci Food Agric. 2020. PMID: 32144775
-
Multi-color quantum dot-based fluorescence immunoassay array for simultaneous visual detection of multiple antibiotic residues in milk.Biosens Bioelectron. 2015 Oct 15;72:320-5. doi: 10.1016/j.bios.2015.05.018. Epub 2015 May 7. Biosens Bioelectron. 2015. PMID: 26002016
-
A review of analytical methods for the determination of aminoglycoside and macrolide residues in food matrices.Anal Chim Acta. 2008 Aug 22;624(1):1-15. doi: 10.1016/j.aca.2008.05.054. Epub 2008 May 29. Anal Chim Acta. 2008. PMID: 18706307 Review.
-
Determination of aminoglycosides and quinolones in food using tandem mass spectrometry: a review.Crit Rev Food Sci Nutr. 2004;44(3):173-84. doi: 10.1080/10408690490441488. Crit Rev Food Sci Nutr. 2004. PMID: 15239371 Review.
Cited by
-
Affinity-Based Analysis Methods for the Detection of Aminoglycoside Antibiotic Residues in Animal-Derived Foods: A Review.Foods. 2023 Apr 8;12(8):1587. doi: 10.3390/foods12081587. Foods. 2023. PMID: 37107381 Free PMC article. Review.
References
-
- Shaikh B, Allen EH. Overview of physical-chemical methods for determining aminoglycoside antibiotics in tissues and fluids of food-producing animals. J Assoc Off Anal Chem. 1985;68(5):1007–13. - PubMed
-
- Clark CH. Clinical uses of gentamicin. Mod Vet Pract. 1977;58(9):751–4. - PubMed
-
- Fuentes VO, Gonzalez H, Sanchez V, Fuentes P, Rosiles R. The effect of neomycin on the kidney function of the horse. Zentralbl Veterinarmed A. 1997;44(4):201–5. - DOI
-
- European Commission. COMMISSION REGULATION (EU) No 37/2010 of 22 December 2009 on pharmacologically active substances and their classification regarding maximum residue limits in foodstuffs of animal origin. Official Journal of the European Union, L: Legislation (English Edition). 2010;15:1–72. https://ec.europa.eu/health/sites/default/files/files/eudralex/vol-5/reg...
-
- Preu M, Guyot D, Petz M. Development of a gas chromatography-mass spectrometry method for the analysis of aminoglycoside antibiotics using experimental design for the optimisation of the derivatisation reactions. J Chromatogr A. 1998;818(1):95–108. - DOI
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical