. 2021 Jun 4;24(5):247-249.
doi: 10.1016/j.jccase.2021.04.015. eCollection 2021 Nov.

Subaortic stenosis secondary to pannus from a mechanical mitral valve

Affiliations
Case Reports

Subaortic stenosis secondary to pannus from a mechanical mitral valve

James E Livesay et al. J Cardiol Cases. .

Abstract

A variety of conditions can lead to left ventricle outflow tract obstruction, but cases of subaortic stenosis decades following a mitral valve replacement are exceedingly rare. Any abnormal positioning of a prosthetic valve can result in continuous turbulence leading to permanent deposition of fibrous tissue. We present a case of a 56-year-old female that underwent mechanical mitral valve replacement, due to severe rheumatic mitral valve disease, with recurrent admissions for dyspnea. Ultimately, she underwent a left heart catheterization and during pullback from the left ventricle to the aorta a 100-mmHg pressure gradient was noted below the level of the aortic valve suggestive of subaortic stenosis. The subaortic stenosis was found to be secondary to pannus formation from her mitral valve prosthesis placed over twenty years ago. <Learning objective: Subaortic stenosis secondary to pannus formation decades following a mechanical mitral valve replacement is exceptionally rare. The diagnosis of subaortic stenosis can be extremely difficult requiring high clinical suspicion, transthoracic and transesophageal echocardiography, computed tomography, and/or pullback pressure during left heart catheterization.>.

Keywords: Mechanical mitral valve; Subaortic stenosis.

PubMed Disclaimer

Conflict of interest statement

The authors declare there are no conflict of interest.

Figures

Fig 1
Fig. 1
Transesophageal echocardiogram, midesophageal long-axis view, showing LVOT turbulence with color flow Doppler.
Fig 2
Fig. 2
Pullback gradient from mid left ventricle to aorta.
Fig 3
Fig. 3
Computed tomography showing a narrowed left ventricular outflow tract due to pannus formation associated with the prosthetic mitral valve.

References

    1. Moldovan M.S., Bedeleanu D., Kovacs E., Ciumărnean L., Molnar A. Pannus-related prosthetic valve dysfunction. Case report. Clujul Med. 2016;89(1):169–175. doi: 10.15386/cjmed-510. - DOI - PMC - PubMed
    1. Mohan J.C., Shukla M., Mohan V., Sethi A. Acquired discrete subaortic stenosis late after mitral valve replacement. Indian Heart J. 2016;68(Suppl 2):S105–S109. doi: 10.1016/j.ihj.2016.01.001. (Suppl 2) - DOI - PMC - PubMed
    1. Kalçık M., Yesin M., Gündüz S., Gürsoy M.O., Bayam E., Özkan M. Left Ventricular Side Obstructive Pannus Formation after Rheumatic Mitral Valve Replacement with Preservation of the Subvalvular Apparatus. Echocardiography. 2015;32(12):1887–1888. doi: 10.1111/echo.13034. - DOI - PubMed
    1. Boutayeb A., Mrini F.E., Bendagha N., Bensouda A., Moughil S. Mitral valve replacement as unusual cause of discrete sub-aortic membrane. Heart Lung Circ. 2015;24(1):e4–e6. doi: 10.1016/j.hlc.2014.09.003. - DOI - PubMed
    1. Cavalcante J.L., Lalude O.O., Schoenhagen P., Lerakis S. Cardiovascular magnetic resonance imaging for structural and valvular heart disease interventions. JACC Cardiovasc Interv. 2016;9(5):399–425. doi: 10.1016/j.jcin.2015.11.031. - DOI - PubMed