Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1986 Jun;203(6):691-700.
doi: 10.1097/00000658-198606000-00015.

Experiences with 1643 porcine prosthetic valves in 1492 patients

Experiences with 1643 porcine prosthetic valves in 1492 patients

F C Spencer et al. Ann Surg. 1986 Jun.

Abstract

Sixteen hundred and forty-three porcine prosthetic values (1102 Carpentier-Edwards, 541 Hancock) were implanted in 1492 patients at New York University Medical Center between January 1976 and June 1983. The aortic valve alone was replaced in 786 patients (53%), mitral valve alone in 556 (37%), and multiple valves in 143 patients (9.6%). Concomitant coronary artery bypass was performed in 326 patients (22%). There were 116 deaths within 30 days of operation (7.8%). Follow-up (mean: 42 months) was completed in 94% of survivors and revealed that late survival from cardiac-related death was 87% at 5 years and 81% at 7 years, with no significant difference between the Carpentier-Edwards and Hancock patients. Late thromboembolic complications, however, were significantly more frequent in Hancock patients at all intervals from 1-7 years (p less than 0.05), whether in the aortic or mitral position. Patients with coronary artery disease who had concomitant coronary bypass showed a survival from late cardiac death that did not differ significantly from that of patients undergoing valve replacement alone. Before operation, 87% of patients were in New York Heart Association Class III or IV, but after operation 80% were in Class I or II. Late anticoagulant complications, endocarditis, and valve dysfunction were relatively rare. These results from a series of such size, duration, and representative numbers of two types of porcine bioprosthesis confirm excellent results with porcine prostheses in the first 4-5 years following operation.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am Surg. 1983 Jan;49(1):6-10 - PubMed
    1. J Thorac Cardiovasc Surg. 1979 Sep;78(3):343-50 - PubMed
    1. J Thorac Cardiovasc Surg. 1984 Jul;88(1):102-13 - PubMed
    1. Ann Thorac Surg. 1982 Sep;34(3):265-77 - PubMed
    1. Circulation. 1980 Aug;62(2):313-8 - PubMed