Zero-Calibrating External Ventricular Drains: Exploring Practice
Abstract
BACKGROUND: Guidelines call for the removal of the nonvented cap (NVC) on the flushless transducer applied to the external ventricular drain (EVD) to zero the device to atmospheric pressure. Some hospitals have abandoned this practice to prevent opening the system to air. No data exist to determine the safest, most effective method of EVD zero-calibration. METHODS: A multidisciplinary team was assembled to use reflective practice to evaluate current zero-calibration of EVD practice. RESULTS: Clinical Nursing Focus showed recommendations largely out of date without detailed rationale or a high level of evidence. Manufacturer recommendations were fragmented and did not address rationale for technique. Bedside trial showed equivalence when comparing intracranial pressure (ICP) tidal, ICP after EVD zero with NVC removal, and ICP after EVD zero without NVC removal. CONCLUSION: Institutional guidelines were changed to reflect zero-calibration of EVD without NVC removal in systems that are amendable to this procedure. Further study is needed to determine best practice.
Copyright © 2021 American Association of Neuroscience Nurses.
Conflict of interest statement
The authors declare no conflicts of interest.
Comment in
-
Letter to Editor in Response to "Zero-Calibrating External Ventricular Drains: Exploring Practice".J Neurosci Nurs. 2022 Jun 1;54(3):107. doi: 10.1097/JNN.0000000000000647. Epub 2022 Apr 2. J Neurosci Nurs. 2022. PMID: 35385424 No abstract available.
References
-
- Lipincott Procedures. External ventricular drain insertion, assisting. Available at https://procedures.lww.com/lnp/view.do?pId=3851768&hits=evd&a=fa... . Accessed December 8, 2020.
-
- Lipincott Procedures. Intracranial pressure catheter insertion, monitoring, and care. Available at https://procedures.lww.com/lnp/view.do?pId=3850683 . Accessed December 8, 2020.
-
- Medtronic Neurologic Technologies. Becker external drainage and monitoring system quick reference guide. Available at https://www.medtronic.com/content/dam/medtronic-com/global/HCP/Documents... . Accessed December 8, 2020.
-
- Thompson H; American Association of Neuroscience Nurses (AANN). Clinical practice guideline series update. J Neurosci Nurs . 2011;43(4):233–235.
-
- Edwards Lifesciences. TruWave pressure monitoring kit with TruWave disposable pressure transducer. Available at https://eifu.edwards.com/eifu/pages/viewers/pdf?projectKey=5970f1b346e0f... . Accessed December 8, 2020.
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous