Comparative Study
. 1986 Aug;30(2):274-80.
doi: 10.1128/AAC.30.2.274.

Failure to detect ampicillin-resistant, non-beta-lactamase-producing Haemophilus influenzae by standard disk susceptibility testing

Comparative Study

Failure to detect ampicillin-resistant, non-beta-lactamase-producing Haemophilus influenzae by standard disk susceptibility testing

P M Mendelman et al. Antimicrob Agents Chemother. 1986 Aug.

Abstract

We questioned whether the apparent rarity of ampicillin-resistant, non-beta-lactamase-producing (NBLP) Haemophilus influenzae was due to failure of detection. We identified ampicillin-resistant and ampicillin-susceptible H. influenzae by the agar dilution technique, using 10(5)- and 10(3)-CFU inocula. We compared the disk susceptibility of 18 ampicillin-resistant NBLP strains, 13 ampicillin-resistant, beta-lactamase-producing strains, and 10 ampicillin-susceptible strains by using standard 10- and 2-micrograms ampicillin disks on two different media. We also investigated the possibility that disks containing 10 micrograms of clavulanic acid and 2 micrograms of ampicillin could be used to distinguish between the two ampicillin-resistant populations. Using the disk containing 2 micrograms of ampicillin, we correctly differentiated all the ampicillin-resistant isolates from the ampicillin-susceptible isolates on both media (a zone diameter of less than or equal to 15 mm was considered resistant). In contrast, the 10-micrograms ampicillin disk failed to detect 44% (8 of 18) of the ampicillin-resistant NBLP strains (a zone diameter of less than or equal to 19 mm was considered resistant). The MIC of ampicillin with the 10(3)-CFU inoculum correlated better with zone diameters than with the 10(5)-CFU inoculum. A difference in zone diameters of greater than or equal to 8 mm between the disk containing 10 micrograms of clavulanic acid and 2 micrograms of ampicillin and the disk containing only 2 micrograms of ampicillin correctly identified all beta-lactamase-producing strains. We conclude that the 2-micrograms ampicillin disk tests more readily identify ampicillin resistance in H. influenzae than do the 10-micrograms ampicillin disk tests. Future investigation should determine whether this in vitro resistance correlates with clinical treatment failures.

PubMed Disclaimer

References

    1. Antimicrob Agents Chemother. 1980 Jan;17(1):80-3 - PubMed
    1. Surg Gynecol Obstet. 1984 Aug;159(2):153-6 - PubMed
    1. Pediatrics. 1980 May;65(5):917-43 - PubMed
    1. Antimicrob Agents Chemother. 1980 Mar;17(3):434-42 - PubMed
    1. Antimicrob Agents Chemother. 1980 Nov;18(5):730-7 - PubMed

Publication types

MeSH terms

LinkOut - more resources