Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Editorial
. 2022 Aug;36(4):921-928.
doi: 10.1007/s10877-021-00780-3. Epub 2021 Dec 17.

Features of new vision-incorporated third-generation video laryngeal mask airways

Affiliations
Editorial

Features of new vision-incorporated third-generation video laryngeal mask airways

André A J Van Zundert et al. J Clin Monit Comput. 2022 Aug.

Abstract

Numerous studies have shown that blindly inserted supraglottic airway devices (SADs) are sub-optimally placed in 50 to 80% of all cases. Placement under direct vision has been recommended. We describe the very first two new SADs of the third generation that incorporate a videoscope with flexible tip. Both devices are made up of two interlocking components-the SAD and a videoscope. The 3rd generation, direct vision SADs allow vision-guided insertion, corrective manoeuvres, if needed, and correct placement in the hypopharynx and possess additional features which permit insertion of a gastric tube and endotracheal intubation should the need arise. This article describes the two new devices' physical characteristics, features, rationale for use, advantages and limitations in comparison to existing devices. Each of the two new devices-the Video Laryngeal Mask (VLMTM, UE Medical®) and the SafeLM® Video Laryngeal Mask System (SafeLMTM VLMS, Magill Medical Technology®) consist of two parts: (a) a disposable 2nd generation SAD with a silicone cuff and an anatomically curved tube; and (b) a reusable patient-isolated videoscope and monitoring screen, with the flexible scope located into a specially-designed, blind-end channel terminating in the bowl of the SAD, preventing the videoscope from contacting patient body fluids in the SAD bowl. Third generation placement-under-direct-vision supraglottic airway devices possess several theoretical safety and ease of use advantages which now need to be validated in clinical use.

Keywords: Airway management; Anaesthesia; Complications; Supraglottic airway device; Videolaryngoscope.

PubMed Disclaimer

References

    1. Brain AIJ. The laryngeal mask—a new concept in airway management. Br J Anaesth. 1983;55:801–5. - DOI
    1. Van Zundert TCRV, Brimacombe JR, Ferson DZ, Bacon DR, Wilkinson DJ. Archie brain: celebrating 30 years of development in laryngeal mask airways. Anaesthesia. 2012;67:1375–85. - DOI
    1. Van Zundert AAJ, Kumar CM, Van Zundert TCRV, Gatt SP, Pandit JJ. The case for a 3rd generation supraglottic airway device facilitating direct vision placement. J Clin Monit Comput. 2021;35:217–24. https://doi.org/10.1007/s10877-020-00537-4 . - DOI - PubMed
    1. Danha RF, Thompson JL, Popat MT, Pandit JJ. Comparison of fibreoptic-guided orotracheal intubation through classic and single-use laryngeal mask airways. Anaesthesia. 2005;60:184–8. - DOI
    1. Frerk C, Mitchell VS, McNarry AF, et al. Difficult Airway Society Intubation Guidelines Working Group. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:828–48. - DOI

Publication types

LinkOut - more resources