The detection of leukocyte esterase activity in urine with a new reagent strip
- PMID: 3492135
- DOI: 10.1093/ajcp/87.1.86
The detection of leukocyte esterase activity in urine with a new reagent strip
Abstract
An evaluation of the Ames Leukostix reagent strips for the detection of leukocyte esterase activity in urine was undertaken to determine the interlot precision and between reader reliability, to compare Leukostix and Chemstrip LN results, and to determine if the Ames Leukostix reagent strip provides an alternative to, or supplement for, the microscopic detection of leukocytes. A total of 412 urines were analyzed with the Ames and Bio-Dynamics reagent strips. The sensitivity and specificity of Leukostix results, relative to a quantitative chamber count, were 89.4% and 90.4%, respectively. Chemstrip LN provided essentially the same results with a sensitivity of 88.8% and specificity of 92.4%. The between-reader and between-lot reproducibility was excellent, with 99% of the results agreeing within half a color block of each other. The sensitivity of the sediment count relative to the chamber count was 68.9% and the specificity, 97.7%. Performance of the sediment count in addition to use of the reagent strip provided little additional information. On the basis of these results, the Ames Leukostix reagent strip is considered to be a suitable alternative to sediment microscopic examination for the detection of leukocytes in urine.
Similar articles
-
New dip-and-read test for determining leukocytes in urine.Clin Chem. 1987 Jul;33(7):1242-5. Clin Chem. 1987. PMID: 3594857
-
Applicability of leukocyte esterase test strip in detection of canine pyuria.J Am Vet Med Assoc. 1986 Dec 1;189(11):1451-3. J Am Vet Med Assoc. 1986. PMID: 3804837
-
A control system for monitoring the performance of leukocyte strip tests.Clin Chem. 1986 Jul;32(7):1400-2. Clin Chem. 1986. PMID: 3719952
-
Measurement of urinary leukocyte esterase activity: a screening test for urinary tract infections.Ann Emerg Med. 1984 Mar;13(3):150-4. doi: 10.1016/s0196-0644(84)80603-4. Ann Emerg Med. 1984. PMID: 6696301
-
Clinical evaluation of a leukocyte esterase test-strip for detection of feline pyuria.Vet Clin Pathol. 1997;26(3):126-131. doi: 10.1111/j.1939-165x.1997.tb00723.x. Vet Clin Pathol. 1997. PMID: 12658590
Cited by
-
Current Guideline for Diagnosis of Periprosthetic Joint Infection: A Review Article.Hip Pelvis. 2021 Mar;33(1):11-17. doi: 10.5371/hp.2021.33.1.11. Epub 2021 Mar 2. Hip Pelvis. 2021. PMID: 33748021 Free PMC article. Review.
-
Rapid, simple, and reliable method for the diagnosis of CAPD peritonitis using the new MMP-9 test kit.J Clin Lab Anal. 2004;18(4):224-30. doi: 10.1002/jcla.20027. J Clin Lab Anal. 2004. PMID: 15202114 Free PMC article.
-
Urine proteomics: the present and future of measuring urinary protein components in disease.CMAJ. 2007 Aug 14;177(4):361-8. doi: 10.1503/cmaj.061590. CMAJ. 2007. PMID: 17698825 Free PMC article. Review.
-
Randomised controlled trial of nitrofurantoin versus placebo in the treatment of uncomplicated urinary tract infection in adult women.Br J Gen Pract. 2002 Sep;52(482):729-34. Br J Gen Pract. 2002. PMID: 12236276 Free PMC article. Clinical Trial.
-
Diagnosing bacterial peritonitis made easy by use of leukocyte esterase dipsticks.Int J Crit Illn Inj Sci. 2015 Jan-Mar;5(1):32-7. doi: 10.4103/2229-5151.152337. Int J Crit Illn Inj Sci. 2015. PMID: 25810962 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources