Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Mar;75(3):1171-1178.
doi: 10.1016/j.bjps.2021.11.043. Epub 2021 Nov 16.

Assessment of deep inferior epigastric perforator flap perfusion with near-infrared fluorescence: A pilot study and description of a standardized working protocol

Affiliations
Free article

Assessment of deep inferior epigastric perforator flap perfusion with near-infrared fluorescence: A pilot study and description of a standardized working protocol

Marlies Michi et al. J Plast Reconstr Aesthet Surg. 2022 Mar.
Free article

Abstract

Fat necrosis (FN) is a common complication after autologous breast reconstruction (ABR) using a free flap, which can influence reconstruction outcome and patient satisfaction. Intraoperative near-infrared fluorescence imaging using indocyanine green (ICG) permits the visualization of flap perfusion. The aim of this study was to assess the effect of near-infrared fluorescence on FN incidence in patients undergoing an ABR with a deep inferior epigastric perforator flap (DIEP) and to propose a standard working protocol for this technique. In this prospective study, patients undergoing one-sided ABR with a DIEP were included. The standard DIEP procedure was complemented with near-infrared fluorescence imaging using the fluorescent tracer ICG to evaluate flap perfusion. This cohort was compared to a retrospective cohort of DIEP procedures without near-infrared fluorescence imaging. Patients and surgery characteristics, as well as postoperative complications, were registered and compared. In both cohorts, 24 patients were included. No significant differences were present between patients and surgery characteristics, including no difference in duration of surgery. In the prospective and retrospective group, the incidence of FN was 4.2% and 33%, respectively (p-value = 0.023). Moreover, microsurgeons were positive about using near-infrared fluorescence as it either provided additional information about perfusion or confirmed the clinical assessment. Our pilot study showed a significant decrease of FN in patients undergoing an ABR with a DIEP when near-infrared fluorescence imaging was used to assess flap perfusion. This study provides a standardized working protocol for near-infrared fluorescence imaging. In the future, large multicenter studies should focus on the quantification of near-infrared fluorescence imaging.

Keywords: Autologous breast reconstruction; Deep inferior epigastric artery perforator (DIEP) flap; Fat necrosis; Fluorescence imaging; Free flap; Perfusion assessment.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest None declared

LinkOut - more resources