Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Apr;53(3):671-682.
doi: 10.1007/s11239-021-02628-8. Epub 2022 Jan 4.

Comparison of biodegradable and newer generation durable polymer drug-eluting stents with short-term dual antiplatelet therapy: a systematic review and Bayesian network meta-analysis of randomized trials comprising of 43,875 patients

Affiliations

Comparison of biodegradable and newer generation durable polymer drug-eluting stents with short-term dual antiplatelet therapy: a systematic review and Bayesian network meta-analysis of randomized trials comprising of 43,875 patients

Bryan Chong et al. J Thromb Thrombolysis. 2022 Apr.

Abstract

Newer generation durable polymer drug-eluting stents (DP-DES) and biodegradable polymer DES (BP-DES) have similar efficacy with dual-antiplatelet therapy (DAPT) duration of > 6 months. However, this difference in outcomes have not been well studied in shorter DAPT regime. This study compares the safety and efficacy profiles of DP-DES and BP-DES based on short-term (1-3 months), intermediate-term (4-6 months) and standard DAPT (6-12 months) durations. A search was conducted on Embase and Medline for Randomized Controlled Trials (RCTs) comparing stent types, and DAPT durations. Primary endpoints include cardiac death, myocardial infarction (MI), definite stent thrombosis, stroke, target vessel revascularization (TVR) and major bleeding. Network analysis was conducted to summarize the evidence. A total of 15 RCTs involving 43,875 patients were included. DP-DES was associated with significantly lower major bleeding rates compared to BP-DES (RR 0.44, Crl 0.22-0.83) in short-term DAPT. Among DP-DES patients, short-term DAPT was associated with lower major bleeding risk compared to standard DAPT (RR 0.47, CrI 0.32-0.69). This favorable bleeding profile with short DAPT was not found in BP-DES patients. Cardiac death, MI, definite stent thrombosis, stroke and TVR rates were similar across the various DAPT durations and stent types. Our preliminary findings demonstrated comparable efficacy and safety outcomes between BP-DES and newer generation BP-DES across various DAPT durations. In patients requiring short DAPT, DP-DES had more favourable major bleeding profile compared to BP-DES, without compromising anti-thrombotic efficacy.

Keywords: Anti-platelet therapy; Biodegradable; Drug-eluting stents; Durable.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Stefanini GG, Holmes DR (2013) Drug-eluting coronary-artery stents. N Engl J Med 368(3):254–265 - PubMed - DOI - PMC
    1. Räber L, Magro M, Stefanini GG et al (2012) Very late coronary stent thrombosis of a newer-generation everolimus-eluting stent compared with early-generation drug-eluting stents. Circulation 125(9):1110–1121 - PubMed - DOI - PMC
    1. Stefanini GG, Windecker S (2012) Stent thrombosis. Circulation 5(3):332–335 - PubMed - PMC
    1. Dores H, Raposo L, Campante Teles R et al (2013) Stent thrombosis with second- versus first-generation drug-eluting stents in real-world percutaneous coronary intervention: analysis of 3806 consecutive procedures from a large-volume single-center prospective registry. J Invasive Cardiol 25(7):330–336 - PubMed - PMC
    1. Naidu SS, Krucoff MW, Rutledge DR et al (2012) Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study. JACC: Cardiovasc Interv 5(6):626–635

Publication types

LinkOut - more resources