Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 May;29(5):3085-3092.
doi: 10.1245/s10434-021-11208-2. Epub 2022 Jan 7.

Robotic Adrenalectomy Using the da Vinci SP Robotic System: Technical Feasibility Comparison with Single-Port Access Using the da Vinci Multi-arm Robotic System

Affiliations

Robotic Adrenalectomy Using the da Vinci SP Robotic System: Technical Feasibility Comparison with Single-Port Access Using the da Vinci Multi-arm Robotic System

In A Lee et al. Ann Surg Oncol. 2022 May.

Abstract

Background: Laparoscopic adrenalectomy is the gold standard for adrenal tumor; however, robotic adrenal surgery has gained interest recently. For minimally invasive surgeries, we first reported on robotic adrenalectomy using a single-port access performed using the da Vinci multi-arm robotic system (RA-SA) in 2011. Since its introduction in 2018, we first performed robotic adrenalectomy using the da Vinci SP robotic system in 2020.

Objective: We aimed to introduce the novel single-port robotic system (RA-SP) for adrenalectomy and evaluate its technical feasibility by comparing it with the surgical outcomes of patients who underwent robotic adrenalectomy using the RA-SA.

Methods: Eight patients who underwent robotic adrenalectomy using the RA-SP from February 2020 to June 2021 were compared with 11 patients who underwent RA-SA from 2011 to 2015 by a single surgeon.

Results: The two groups were similar in age, sex, body mass index, type of operation, and final pathologic diagnosis. Despite no significant differences, RA-SP resulted in moderately less mean operation time, estimated blood loss, and length of hospitalization.

Conclusions: The Da Vinci SP robotic system is a novel, safe, and feasible technique to improve the convenience of operation and cosmetic effect for adrenalectomy.

PubMed Disclaimer

References

    1. Gagner M, Lacroix A, Bolte E. Laparoscopic adrenalectomy in Cushing’s syndrome and pheochromocytoma. N Engl J Med. 1992;327(14):1033. - DOI
    1. Callender GG, Kennamer DL, Grubbs EG, Lee JE, Evans DB, Perrier ND. Posterior retroperitoneoscopic adrenalectomy. Adv Surg. 2009;43(1):147–57. - DOI
    1. Lee CR, Walz MK, Park S, et al. A comparative study of the transperitoneal and posterior retroperitoneal approaches for laparoscopic adrenalectomy for adrenal tumors. Ann Surg Oncol. 2012;19(8):2629–34. - DOI
    1. Kozłowski T, Choromanska B, Wojskowicz P, et al. Laparoscopic adrenalectomy: lateral transperitoneal versus posterior retroperitoneal approach–prospective randomized trial. Videosurg Other Miniinvasive Tech. 2019;14(2):160. - DOI
    1. Gavriilidis P, Camenzuli C, Paspala A, Di Marco AN, Palazzo FF. Posterior retroperitoneoscopic versus laparoscopic transperitoneal adrenalectomy: a systematic review by an updated meta-analysis. World J Surg. 2021;45(1):168–79. - DOI

LinkOut - more resources