Couple batch-injection analysis and microfluidic paper-based analytical device: A simple and disposable alternative to conventional BIA apparatus
- PMID: 34998146
- DOI: 10.1016/j.talanta.2021.123201
Couple batch-injection analysis and microfluidic paper-based analytical device: A simple and disposable alternative to conventional BIA apparatus
Abstract
Under controlled dispersion conditions, sample injection towards a detector opened essential fields for the Analytical Chemistry fast development methods. Flow injection analysis (FIA) and batch injection analysis (BIA) systems are crucial for injecting the sample in these analytical methods. The BIA system eliminated the flow manifold, with samples injected directly onto the detector inside the batch injection cell. Paper was slightly evaluated coupled to FIA, and no reports were found associated with BIA. Still, it can potentially reduce the BIA manifold by removing the batch injection cell based on the capillarity properties to disperse the injected solution over the detection system. Hence, this article reported the first work coupling batch-injection analysis and microfluidic paper-based analytical device (BIA-μPAD) with pencil-drawn electrodes directly attached to the paper using a CO2 laser pre-treated chromatographic paper. The laser pretreatment of the paper (optimized conditions: 6.5% laser power, 12 mm s-1 scan rate, and 12 mm output distance) was essential to enhance the electrochemical response for ferri/ferrocyanide redox couple and paracetamol (PAR), as shown by spectroscopic and electrochemical techniques. The proposed BIA-μPAD was evaluated using pharmaceutical paracetamol samples as proof-of-concept (optimized conditions: 15 μL injected volume and 6.4 μL s-1 dispensing rate), obtaining good linearity (R = 0.9961) and recovery values ranging from 95 to 103%. Repeatability (n = 16) and reproducibility (n = 9) tests with 1 mmol L-1 PAR also presented well relative standard deviation (RSD) results of 5.1% and 6.6%, respectively. A sampling frequency of 76 h-1 was obtained, which is a similar value compared with conventional BIA apparatus. Limits of detection and quantification were estimated in 0.046 and 0.154 mmol L-1, respectively. Additionally, an improvement in the current response and the sample throughput was observed when comparing FIA and BIA-μPADs, attesting the applicability of the proposed device and opening for new possibilities related to paper-based devices coupled with flow techniques.
Keywords: Batch injection analysis; CO(2) laser pretreatment; Carbon electrodes; Electrochemical detection; Paper-based devices; Paracetamol; Pencil-drawing.
Copyright © 2021 Elsevier B.V. All rights reserved.
Similar articles
-
Extruded filament electrodes for lactate biosensing in continuous-injection paper-based microfluidic devices.Biosens Bioelectron. 2025 Jun 15;278:117390. doi: 10.1016/j.bios.2025.117390. Epub 2025 Mar 24. Biosens Bioelectron. 2025. PMID: 40128136
-
3D-printed electrochemical platform with multi-purpose carbon black sensing electrodes.Mikrochim Acta. 2022 May 28;189(6):235. doi: 10.1007/s00604-022-05323-4. Mikrochim Acta. 2022. PMID: 35633399 Free PMC article.
-
Laser engraved microapillary pump paper-based microfluidic device for colorimetric and electrochemical detection of salivary thiocyanate.Mikrochim Acta. 2021 Mar 26;188(4):140. doi: 10.1007/s00604-021-04793-2. Mikrochim Acta. 2021. PMID: 33772376
-
Enzyme embedded microfluidic paper-based analytic device (μPAD): a comprehensive review.Crit Rev Biotechnol. 2021 Nov;41(7):1046-1080. doi: 10.1080/07388551.2021.1898327. Epub 2021 Mar 17. Crit Rev Biotechnol. 2021. PMID: 33730940 Review.
-
Electrochemical microfluidic paper-based analytical devices for cancer biomarker detection: From 2D to 3D sensing systems.Talanta. 2023 May 15;257:124370. doi: 10.1016/j.talanta.2023.124370. Epub 2023 Feb 16. Talanta. 2023. PMID: 36858013 Review.
Cited by
-
[Advances in microchip electrophoresis for the separation and analysis of biological samples].Se Pu. 2023 Aug;41(8):641-650. doi: 10.3724/SP.J.1123.2022.12004. Se Pu. 2023. PMID: 37534551 Free PMC article. Review. Chinese.
-
Application of Paper-Based Microfluidic Analytical Devices (µPAD) in Forensic and Clinical Toxicology: A Review.Biosensors (Basel). 2023 Jul 18;13(7):743. doi: 10.3390/bios13070743. Biosensors (Basel). 2023. PMID: 37504142 Free PMC article. Review.
-
Recent Developments in Microfluidic Paper-based Analytical Devices for Pharmaceutical Analysis.Curr Top Med Chem. 2022;22(27):2241-2260. doi: 10.2174/1568026623666221027144310. Curr Top Med Chem. 2022. PMID: 36305123
MeSH terms
LinkOut - more resources
Full Text Sources