. 2022 Feb;52(2):193-199.
doi: 10.1007/s40279-021-01619-2. Epub 2022 Jan 10.

Longing for a Longitudinal Proxy: Acutely Measured Surface EMG Amplitude is not a Validated Predictor of Muscle Hypertrophy

Affiliations

Longing for a Longitudinal Proxy: Acutely Measured Surface EMG Amplitude is not a Validated Predictor of Muscle Hypertrophy

Andrew D Vigotsky et al. Sports Med. 2022 Feb.

Abstract

Surface electromyography amplitudes are commonly measured in acute sports and exercise science studies to make inferences about muscular strength, performance, and hypertrophic adaptations that may result from different exercises or exercise-related variables. Here, we discuss the presumptive logic and assumptions underlying these inferences, focusing on hypertrophic adaptations for simplicity's sake. We present counter-evidence for each of its premises and discuss evidence both for and against the logical conclusion. Given the limited evidence validating the amplitude of surface electromyograms as a predictor of longitudinal hypertrophic adaptations, coupled with its weak mechanistic foundation, we suggest that acute comparative studies that wish to assess stimulus potency be met with scrutiny.

PubMed Disclaimer

References

    1. Vigotsky AD, Halperin I, Lehman GJ, Trajano GS, Vieira TM. Interpreting signal amplitudes in surface electromyography studies in sport and rehabilitation sciences. Front Physiol. 2018;8:985. - PubMed - PMC
    1. Zajac FE. Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. Crit Rev Biomed Eng. 1989;17(4):359–411. - PubMed
    1. Vieira TM, Bisi MC, Stagni R, Botter A. Changes in tibialis anterior architecture affect the amplitude of surface electromyograms. J Neuroeng Rehabil. 2017;14(1):81. - PubMed - PMC
    1. Lanza MB, Balshaw TG, Folland JP. Do changes in neuromuscular activation contribute to the knee extensor angle–torque relationship? Exp Physiol. 2017;102(8):962–73. - PubMed
    1. Marsh E, Sale D, McComas AJ, Quinlan J. Influence of joint position on ankle dorsiflexion in humans. J Appl Physiol Respir Environ Exerc Physiol. 1981;51(1):160–7. - PubMed

LinkOut - more resources