aEEG vs cEEG's sensivity for seizure detection in the setting of neonatal intensive care units: A systematic review and meta-analysis

Affiliations
Meta-Analysis

aEEG vs cEEG's sensivity for seizure detection in the setting of neonatal intensive care units: A systematic review and meta-analysis

Raffaele Falsaperla et al. Acta Paediatr. 2022 May.

Abstract

Aim: Amplitude-integrated electroencephalography (aEEG)'s accuracy compared to conventional electroencephalography (cEEG) has not been fully established. The aim of our study was to conduct a systematic review on the sensitivity of the aEEG for neonatal seizure detection.

Methods: Studies from PubMed and Google Scholar databases comparing recordings of cEEG and aEEG in newborns were included according to the PRISMA method. A quality assessment using the QUADAS-2 tool was provided. A random-effect model was used to account for different sources of variations among studies. Publication biases were represented by a funnel plot, and funnel plot symmetry was assessed.

Results: Fourteen studies were reported; sensitivity of each diagnostic tool used (single-channel aEEG, two-channel aEEG, two-channel aEEG plus raw trace EEG) was compared to that of the gold-standard cEEG and to those of the other methods used. Overall sensitivity of the aEEG ranged from 31.25% to 90%.

Conclusion: Our study provides evidence that sensitivity of aEEG varies significantly and that seizure detection rate is lower than that of cEEG. The two-channel aEEG with raw trace EEG shows a high sensitivity and might represent a valid alternative to the cEEG in the setting of neonatal intensive care units (NICUs).

Keywords: CFM; EEG monitoring; electroencephalography; neonatal seizures; sensitivity; specificity.

PubMed Disclaimer

References

REFERENCES

    1. Vasudevan C, Levene M. Epidemiology and aetiology of neonatal seizures. Semin Fetal Neonatal Med. 2013;18(4):185-191.
    1. Scher MS, Aso K, Beggarly ME, Hamid MY, Steppe DA, Painter MJ. Electrographic seizures in preterm and full-term neonates: clinical correlates, associated brain lesions, and risk for neurologic sequelae. Pediatrics. 1993;91(1):128-134.
    1. Pisani F, Facini C, Pavlidis E, Spagnoli C, Boylan G. Epilepsy after neonatal seizures: literature review. Eur J Paediatr Neurol. 2015;19(1):6-14.
    1. Van Rooij LGM, Toet MC, van Huffelen AC, et al. Effect of treatment of subclinical neonatal seizures detected with aEEG: randomized, controlled trial. Pediatrics. 2010;125(2):e358-e366.
    1. Shah DK, Wusthoff CJ, Clarke P, et al. Electrographic seizures are associated with brain injury in newborns undergoing therapeutic hypothermia. Arch Dis Child Fetal Neonatal Ed. 2014;99(3):F219-F224.