First Experiences with Implantation of Phakic Lenses in Correction of Myopia in R. N. Macedonia
- PMID: 35032378
- DOI: 10.2478/prilozi-2021-0033
First Experiences with Implantation of Phakic Lenses in Correction of Myopia in R. N. Macedonia
Abstract
Objective: Analysis of visual acuity parameters in patients with moderate to high myopia and myopic astigmatism 1 year after treatment with phakic intraocular lenses. Material and methods: This was a retrospective study on 35 patients (52 eyes) with moderate to high myopia who were implanted with the Visian V4c phakic implantable Collamer lens (Staar Surgical, Nidau, Switzerland). Examined parameters were: uncorrected distance visual acuity (UDVA) and best corrected visual acuity (CDVA), manifest and cycloplegic refraction, intraocular pressure, and endothelial cell count. The investigated parameters were measured preoperatively, 1, 3, 6 and 12 months postoperatively. Results: In 17 patients, phakic lenses were implanted binocularly and in 18 patients monocularly. Preoperatively 34.62% of patients had CDVA from 0.9 to 1.0. One year after the surgery 48.08% of patients had UDVA from 0.9 to 1.0. Preoperatively 80.77% of patients had diopter range from -6.00 Dsph to -10.00 Dsph. At 1 year postoperatively 78.85% of patients were within 0.00 Dsph to -1.00 Dsph. Preoperatively, in patients with astigmatism -4 Dcyl to -2 Dcyl dominated, as opposed to significant improvement postoperatively when 94.23% had astigmatism ranging from -1.0 Dcyl to 0 Dcyl. Conclusion: The implantation of phakic lenses demonstrated a successful postoperative outcome in the treatment of myopia and myopic astigmatism. Visual acuity and refraction show a gradual and significant improvement in visual function parameters within 1 year of lens implantation.
Keywords: astigmatism; diopter; lenses; myopia; visual acuity.
© 2021 Ioannis Chrysikos, published by Sciendo.
References
-
- 1. Kohnen T, Strenger A, Klaproth OK. Basic knowledge of refractive surgery. Deutsches Arzteblatt International, 2008; 105: 163–172.10.3238/arztebl.2008.0163
-
- 2. Niu L, Miao H, Han T, et al. Visual outcomes of Visian ICL implantation for high myopia in patients with shallow anterior chamber depth. BMC Ophthalmology (2019) 19:121.10.1186/s12886-019-1132-z
-
- 3. Oakley CL, Nigro MA, Vote BJ. Fifty-year follow-up and Strampelli anterior chamber intraocular lens. GMS Ophthalmol Cases. 2015;5:Doc 06.
-
- 4. Sanders DR, Doney K, Poco M. ICL in Treatment of Myopia (ITM) Study Group. United States Food and Drug Administration clinical trial of the implantable collamer lens (ICL) for moderate to high myopia: three-year follow-up. Ophthalmology 2004; 111: 1683–9210.1016/j.ophtha.2004.03.026
-
- 5. Kohnen T, Knorz MC, Neuhann T;German Ophthalmological Society;Professional Association of German Ophthalmologists.Evaluation and quality assurance of refractive surgery procedures by the German Ophthalmological Society and the Professional Association of German Ophthalmologists [in German]. Ophthalmologe.2007;104(8):719–726.10.1007/s00347-007-1580-3