Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jan 7:2022:1703806.
doi: 10.1155/2022/1703806. eCollection 2022.

Ocular Manifestations, Visual Field Pattern, and Visual Field Test Performance in Traumatic Brain Injury and Stroke

Affiliations

Ocular Manifestations, Visual Field Pattern, and Visual Field Test Performance in Traumatic Brain Injury and Stroke

Yun Jeong Lee et al. J Ophthalmol. .

Abstract

Purpose: To analyze ocular manifestations, visual field (VF) pattern, and VF test performance in traumatic brain injury (TBI) and stroke patients.

Methods: This retrospective, cross-sectional study included 118 patients (236 eyes) with TBI and stroke who had undergone VF testing by standard automated perimetry with the central 24-2 threshold test. Clinical features including best-corrected visual acuity (BCVA), intraocular pressure (IOP), ocular manifestations, and VF test results including VF defect pattern, reliability, and global indices were analyzed and compared between the TBI and stroke patients.

Results: In TBI patients, ocular manifestations included strabismus (11.1%), cataract (4.2%), and glaucoma suspect (2.8%), whereas in stroke patients, cataract (15.2%), strabismus (8.5%), diabetic retinopathy (4.9%), extraocular movement (EOM) limitation (3.0%), glaucoma suspect (3.0%), nystagmus (2.4%), drusen (1.2%), and vitreous hemorrhage (1.2%) were found. The VF test results showed that 47 eyes (85.5%) in TBI and 86 (65.2%) in stroke had VF defect; in TBI, the scattered pattern was the most common (56.4%), followed by homonymous hemianopsia (14.5%), homonymous quadrantanopia (10.9%), and total defect (3.6%), whereas in stroke, homonymous hemianopsia was the most common (31.8%), followed by scattered pattern (16.7%), homonymous quadrantanopia (12.1%), and total defect (4.5%). Only 15 eyes (27.3%) in TBI and 32 (24.2%) in stroke showed reliable VF indices. The mean deviation (MD) was -10.5 ± 7.1 dB in TBI and -9.5 ± 6.8 dB in stroke, and the pattern standard deviation (PSD) was 4.9 ± 3.3 dB in TBI and 6.1 ± 3.9 dB in stroke, without statistically significant differences between the two groups.

Conclusion: Various ocular manifestations were found, and a considerable proportion of patients were experiencing VF defects and showed unreliable VF test performance. Our findings suggest that accurate evaluation and rehabilitation of visual function should be a matter of greater concern and emphasis in the management of TBI and stroke patients, besides systemic diseases.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflicts of interest.

References

    1. Ventura R. E., Balcer L. J., Galetta S. L. The neuro-ophthalmology of head trauma. The Lancet Neurology . 2014;13(10):1006–1016. doi: 10.1016/s1474-4422(14)70111-5. - DOI - PubMed
    1. Johnson C. O., Nguyen M., Roth G. A. Global, regional, and national burden of stroke, 1990–2016: a systematic analysis for the Global Burden of Disease Study 2016. The Lancet Neurology . 2019;18(5):439–458. - PMC - PubMed
    1. Langlois J. A., Sattin R. W. Preface. The Journal of Head Trauma Rehabilitation . 2005;20(3):187–188. doi: 10.1097/00001199-200505000-00001. - DOI - PubMed
    1. Mackay J., Mensah G. A. The Atlas of Heart Disease and Stroke . Geneva, Switzerland: World Health Organization; 2004. http://www.who.int/cardiovascular_diseases/en/cvd_atlas_15_burden_stroke....
    1. Maas A. I. R., Menon D. K., Adelson P. D., et al. Traumatic brain injury: integrated approaches to improve prevention, clinical care, and research. The Lancet Neurology . 2017;16(12):987–1048. doi: 10.1016/S1474-4422(17)30371-X. - DOI - PubMed

LinkOut - more resources