Spectral analysis of EEG during carotid endarterectomy
- PMID: 3504678
- DOI: 10.1016/S0890-5096(06)60711-5
Spectral analysis of EEG during carotid endarterectomy
Abstract
Spectral analysis of the electroencephalogram (EEG) was monitored during 105 carotid endarterectomies. Seventy-eight percent of the patients showed no significant change in EEG spectral power as a result of clamping of the internal carotid artery. Two patterns of change were observed in the remaining 22% of patients: partial reduction (significant decrease of power in one or two of three frequency bands) and global reduction (significant decrease of power in all three frequency bands). High frequencies (over 10.5 Hz) changed more frequently with clamping than did low frequencies (less than 6 Hz), but reduction of high frequencies alone was tolerated with no postoperative deficits. The only non-shunted patient demonstrating global EEG reduction for the duration of carotid clamping suffered a transient hemiparesis.
Similar articles
-
Role of EEG monitoring and cross-clamping duration in carotid endarterectomy.J Neurosurg. 1986 Dec;65(6):815-9. doi: 10.3171/jns.1986.65.6.0815. J Neurosurg. 1986. PMID: 3772480
-
Clinical experience with carotid stump pressure and EEG monitoring to determine shunt placement during carotid endarterectomy.J Natl Med Assoc. 1983 Jun;75(6):583-7. J Natl Med Assoc. 1983. PMID: 6876190 Free PMC article.
-
EEG monitoring during carotid endarterectomy.Aust N Z J Surg. 1988 Apr;58(4):285-8. doi: 10.1111/j.1445-2197.1988.tb01057.x. Aust N Z J Surg. 1988. PMID: 3254133 Clinical Trial.
-
Intraoperative assessment of carotid endarterectomy by electromagnetic blood flow measurements.Surg Gynecol Obstet. 1984 May;158(5):457-60. Surg Gynecol Obstet. 1984. PMID: 6231737
-
The value of intraoperative EEG monitoring during carotid endarterectomy.Ann Neurol. 1986 Oct;20(4):508-12. doi: 10.1002/ana.410200411. Ann Neurol. 1986. PMID: 3789666
Cited by
-
Guidelines for intraoperative neuromonitoring using raw (analog or digital waveforms) and quantitative electroencephalography: a position statement by the American Society of Neurophysiological Monitoring.J Clin Monit Comput. 2009 Dec;23(6):369-90. doi: 10.1007/s10877-009-9191-y. Epub 2009 Sep 16. J Clin Monit Comput. 2009. PMID: 19757102
MeSH terms
LinkOut - more resources
Full Text Sources
Medical