A Comparison of Various Chips Used for the Manufacture of Biosensors Applied in Non-Fluidic Array SPRi, Based on the Example of Determination of Cathepsin D
- PMID: 35049649
- PMCID: PMC8773720
- DOI: 10.3390/bios12010021
A Comparison of Various Chips Used for the Manufacture of Biosensors Applied in Non-Fluidic Array SPRi, Based on the Example of Determination of Cathepsin D
Abstract
Non-fluidic array SPR imaging (SPRi) with appropriate biosensors is a new tool for the determination of various biomarkers in body fluids. Numerous biomarkers can be determined without signal enhancement or preliminarily preconcentration. The introduction of a new material solution of the chip may increase the scope of the application of this technique. Solutions with adhesive separating foil and an Ag/Au chip were compared with the previously used two-paint separating polymer and pure gold chip. These solutions were tested using the example of a biosensor for cathepsin D (Cath D), which consisted of pepstatin A (a Cath D inhibitor) immobilized via a cysteamine linker using the NHS/EDC protocol. Four material versions of the Cath D biosensor proved adequate in terms of range of linearity, LOQ, precision and recovery. All four versions of the biosensor were used for the determination of Cath D in the blood serum patients with glioblastoma and control samples, producing very similar results and showing an elevated biomarker concentration in the case of cancer. Therefore, the problem of determining the correct level of Cath D in the serum of healthy individuals has been resolved, correcting literature data which ranged over three orders of magnitude.
Keywords: Ag/Au chip; adhesive separating foil; array SPRi; blood serum; cathepsin D; glioblastoma.
Conflict of interest statement
The authors declare no conflict of interest.
Figures



Similar articles
-
An Immunosensor for the Determination of Cathepsin S in Blood Plasma by Array SPRi-A Comparison of Analytical Properties of Silver-Gold and Pure Gold Chips.Biosensors (Basel). 2021 Aug 27;11(9):298. doi: 10.3390/bios11090298. Biosensors (Basel). 2021. PMID: 34562888 Free PMC article.
-
Two SPRi biosensors for the determination of cathepsin S in blood plasma.Talanta. 2021 Apr 1;225:121900. doi: 10.1016/j.talanta.2020.121900. Epub 2020 Dec 4. Talanta. 2021. PMID: 33592693
-
SPR imaging biosensor for aspartyl cathepsins: sensor development and application for biological material.Protein Pept Lett. 2010 Sep;17(9):1148-54. doi: 10.2174/092986610791760450. Protein Pept Lett. 2010. PMID: 20394580
-
Surface plasmon resonance: a versatile technique for biosensor applications.Sensors (Basel). 2015 May 5;15(5):10481-510. doi: 10.3390/s150510481. Sensors (Basel). 2015. PMID: 25951336 Free PMC article. Review.
-
SPR and SPR Imaging: Recent Trends in Developing Nanodevices for Detection and Real-Time Monitoring of Biomolecular Events.Sensors (Basel). 2016 Jun 14;16(6):870. doi: 10.3390/s16060870. Sensors (Basel). 2016. PMID: 27314345 Free PMC article. Review.
Cited by
-
Recent advances in surface plasmon resonance for the detection of ovarian cancer biomarkers: a thorough review.Mikrochim Acta. 2024 Oct 9;191(11):659. doi: 10.1007/s00604-024-06740-3. Mikrochim Acta. 2024. PMID: 39382786 Review.
-
Cathepsin B, D and S as Potential Biomarkers of Brain Glioma Malignancy.J Clin Med. 2022 Nov 15;11(22):6763. doi: 10.3390/jcm11226763. J Clin Med. 2022. PMID: 36431239 Free PMC article.
-
Comparison of Fluidic and Non-Fluidic Surface Plasmon Resonance Biosensor Variants for Angular and Intensity Modulation Measurements.Sensors (Basel). 2023 Dec 18;23(24):9899. doi: 10.3390/s23249899. Sensors (Basel). 2023. PMID: 38139744 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources