. 2022 Jan 8;9(1):16.
doi: 10.3390/jcdd9010016.

News from the Cold Chamber: Clinical Experiences of POLARx versus Arctic Front Advance for Single-Shot Pulmonary Vein Isolation

Affiliations

News from the Cold Chamber: Clinical Experiences of POLARx versus Arctic Front Advance for Single-Shot Pulmonary Vein Isolation

Denise Guckel et al. J Cardiovasc Dev Dis. .

Abstract

Cryoballoon (CB)-guided pulmonary vein isolation (PVI) represents a cornerstone in the treatment of atrial fibrillation (AF). Recently, a novel balloon-guided single shot device (POLARx, Boston Scientific) was designed. Our study aimed to compare the efficacy, safety and characteristics of the novel CB system with the established one (Arctic Front Advance (Pro), AFA, Medtronic). A total number of 596 patients undergoing CB-guided ablation for AF were included. 65 patients (65.0 ± 11.6, 31% female) undergoing PVI with the POLARx were compared to a cohort of 531 consecutive patients (63.0 ± 27.9, 25% female) treated with AFA. Acute PVI was achieved in all patients (n = 596, 100%). Total procedure duration (POLARx 113.3 ± 23.2 min, AFA 100.9 ± 21.3 min; p < 0.001) and fluoroscopy time (POLARx 10.5 ± 5.9 min, AFA 4.8 ± 3.6 min; p < 0.001) were significantly longer in the POLARx group. The POLARx balloon achieved significantly lower nadir temperatures (POLARx -57.7 ± 0.9 °C, AFA -45.1 ± 2.6 °C; p < 0.001) and a significantly higher percentage of pulmonary veins successfully isolated with the first freeze (p = 0.027 *). One major complication occurred in the POLARx (2%) and three (1%) in the AFA group. Both ablation systems are comparably safe and effective. AF ablation utilizing the POLARx system is associated with longer procedure and fluoroscopy times as well as lower nadir temperatures.

Keywords: atrial fibrillation; catheter ablation; cryoballoon; single-shot ablation devices.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Novel diaphragm movement sensor (DMS). (A) The novel diaphragm movement sensor is placed on an electrode below the right-sided costal cartilage. (B) Section of the SMARTFREEZE Cryoablation Console surface with visualization of the DMS during pacing of the right-sided phrenic nerve and isolation of the right inferior pulmonary vein.
Figure 2
Figure 2
Fluoroscopic example of LSPV freezing. (A) LSPV freezing with the POLARx compared to the (B) AFA CBA catheter. CBA, cryoballoon ablation.

References

    1. Hindricks G., Potpara T., Dagres N., Arbelo E., Bax J.J., Blomström-Lundqvist C., Boriani G., Castella M., Dan G.A., Dilaveris P.E., et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC. Eur Heart J. 2021;42:373–498. - PubMed
    1. Calkins H., Hindricks G., Cappato R., Kim Y.H., Saad E.B., Aguinaga L., Akar J.G., Badhwar V., Brugada J., Camm J., et al. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2018;20:e1–e160. doi: 10.1093/europace/eux274. - DOI - PMC - PubMed
    1. Asad Z.U.A., Yousif A., Khan M.S., Al-Khatib S.M., Stavrakis S. Catheter Ablation Versus Medical Therapy for Atrial Fibrillation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. Circ. Arrhythm Electrophysiol. 2019;12:e007414. doi: 10.1161/CIRCEP.119.007414. - DOI - PubMed
    1. Unland R., Bergau L., El Hamriti M., Guckel D., Piran M., Fink T., Sciacca V., Köerperich H., Chmelevsky M., Imnadze G., et al. Find Me If You Can: First Clinical Experience Using the Novel CARTOFINDER Algorithm in a Routine Workflow for Atrial Fibrillation Ablation. J. Clin. Med. 2021;10:2979. doi: 10.3390/jcm10132979. - DOI - PMC - PubMed
    1. Kuck K.H., Brugada J., Furnkranz A., Metzner A., Ouyang F., Chun K.R., Elvan A., Arentz T., Bestehorn K., Pocock S.J., et al. FIRE AND ICE Investigators. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N. Engl. J. Med. 2016;374:2235–2245. doi: 10.1056/NEJMoa1602014. - DOI - PubMed